  • Page 1 MU-Thermocouple1 CAN Temperature Measurement Unit with CAN Connection User Manual...
  • Page 2 MU-Thermocouple1 CAN – User Manual Products taken into account Product Name Model Item Number MU-Thermocouple1 CAN Metal-cased measuring unit IPEH-002205 (MU-TC1 CAN) with 8 measuring channels The cover page shows the product MU-TC1 CAN with thermocouple connectors for the type J (black). Versions with assemblies for other thermocouple types have an identical casing design.
  • Page 3: Table Of Contents

    MU-Thermocouple1 CAN – User Manual Contents Introduction Properties at a Glance Prerequisites for the Operation Scope of Supply Connectors Thermocouple Sockets CAN (D-Sub Connector) Supplying External Devices via the CAN Connector Power Supply Socket Safety Instructions Operation with Default Configuration...
  • Page 4: Introduction

    MU-Thermocouple1 CAN – User Manual Introduction The measuring unit Thermocouple1 MU-CAN (short: MU-TC1 CAN) provides terminals for 8 thermocouples for various temperature ranges. The readings are preprocessed by a microcontroller and then transmitted via CAN bus. The corresponding configuring is done with a Windows program on a computer that is connected to the same CAN bus.
  • Page 5: Prerequisites For The Operation

    MU-Thermocouple1 CAN – User Manual Prerequisites for the Operation The following prerequisites must be given, so that the measuring unit can be used properly: Power supply 12 V DC nominal (6 - 32 V possible), connected via supplied mating connector...
  • Page 6: Connectors

    MU-Thermocouple1 CAN – User Manual Connectors This chapter deals with all connectors on the measuring unit. Thermocouple Sockets The measuring unit MU-TC1 CAN supports the following types of thermocouples (according to the assembly of the measuring unit): Type Color (IEC 584)
  • Page 7: Can (D-Sub Connector)

    MU-Thermocouple1 CAN – User Manual CAN (D-Sub Connector) A High-speed CAN bus (ISO 11898-2) is connected to the 9-pin D-Sub connector. The pin assignment corresponds to the CiA recommendation 102 DS. Figure 2: Pin assignment High-speed CAN bus (view onto the male D-Sub connector of the measuring unit)
  • Page 8 MU-Thermocouple1 CAN – User Manual Attention! Risk of short circuit! The measuring unit's electronics or connected electronics may be damaged. If the option described in this section is activated, you may only connect or disconnect CAN cables or peripheral devices (e.g.
  • Page 9: Power Supply Socket

    MU-Thermocouple1 CAN – User Manual Power Supply Socket The measuring unit is operated with 12 V DC, 6 to 34 V are possible. The connection is done with the supplied mating connector for fastening cable strands. The polarity is as follows:...
  • Page 10: Use

    MU-Thermocouple1 CAN – User Manual Safety Instructions Attention! Danger due to electric shock! Risk of destroying the measuring unit! You may only measure temperatures on energized parts, when these are not directly connected with the mains voltage (mea- suring category CAT I). The measuring unit must not be used in the measuring categories CAT II, CAT III, or CAT IV.
  • Page 11 MU-Thermocouple1 CAN – User Manual 3.2.1 CAN Data With the default configuration the measuring values of the eight measuring channels are transmitted via CAN as follows: Property Value CAN IDs 100h, 101h Data bytes 2 per measuring channel (8 per CAN message) Contents per measuring channel 16-bit value: 16th °C...
  • Page 12: Configuring The Measuring Unit

    MU-Thermocouple1 CAN – User Manual Configuring the Measuring Unit If the default configuration for measuring data transmission as des- cribed in section 3.2 doesn't fit your needs, you can configure the measuring unit MU-TC1 CAN with Windows software via a CAN connection.
  • Page 13: Simple Configuring

    MU-Thermocouple1 CAN – User Manual Simple Configuring With the help of the supplied Windows program Thermocouple Configuration you can easily change the following settings regar- ding the measuring data: Block-wise assignment of CAN IDs to the measuring channels 1A to 2B and 3A to 4B...
  • Page 14: Advanced Configuring

    MU-Thermocouple1 CAN – User Manual 4.2.2 Doing Simple Configuring The program Thermocouple Configuration guides you through the configuring procedure step by step. The created configuration may not only be sent to the measuring unit but also saved on a data carrier (CANdb format).
  • Page 15: Technical Specifications

    MU-Thermocouple1 CAN – User Manual Technical Specifications Measuring modules Supported thermocouple types J (-210 - +1121 °C) (IEC 584) K (-200 - +1370 °C) T (-200 - +400 °C) (according to equipment) Connectors Thermocouple socket with standard size (DIN EN...
  • Page 16 MU-Thermocouple1 CAN – User Manual Supply Supply voltage Nominal 12 V DC (6 - 34 V possible) Current consumption ca. 100 mA at 12 V Measures Size 130 x 60 x 73 mm (5 1/8 x 2 3/8 x 2 7/8 inches) (incl.
  • Page 17: Appendix Ace Certificate

    MU-Thermocouple1 CAN – User Manual Appendix A CE Certificate...
  • Page 18: Appendix B Dimension Drawings

    MU-Thermocouple1 CAN – User Manual Appendix B Dimension Drawings Figure 5: Front panel size Figure 6: Mounting plate size All data in millimeters (mm). The figures don't show the original size.