8. Level 3 Repair
8-4-6. Cable Charging Part (Normal/Fast)
Insert TA / USB
Charging Sequence Start
VBUS_IF_5P0(C6036) = 5V or 9V
Check the
CHG_IN_5P0(C6035)=5V or 9V
Battery is Charging?
Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
YES
YES
YES
YES
END
NO
NO
NO
Replace SUB PBA
Replace U6002
Replace U5002