Download Print this page

Main Menu; Configuration Menu - Nilfisk-Advance 56305519 Installation Instructions Manual

Back-up alarm kit

Advertisement

Condor XL / ER1300, ER1600 / SC8000 PROGRAMMING INSTRUCTIONS
1
Press and hold the Hazard (A) and Headlight Switches (B) simultaneously. Turn the Keyswitch (C) ON and wait until the Display (D) reads
"Confi guration Menu" as shown.
2
Press the Side Broom Raise (E) or Lower (F) switches to scroll through the list of available options.
3
Once you see the appropriate option on the Display Panel (D) press the Scrub ON Switch (G) to enter the sub menu for that option.
4
Once in the option sub menu, press the Side Broom Raise (E) or Lower (F) switches to switch between "Not Installed" and "Installed" and then
press the Scrub ON Switch (G) at "Installed" to enable the option. NOTE: Pressing the Scrub OFF Switch (H) at any time will take you back to
the previous level in the menu.
5
Turn the Keyswitch (C) OFF.
© 2013 Nilfi sk-Advance, Inc.

MAIN MENU

CONFIGURATION MENU

Back-Up Alarm
Lights
OPTION SUB MENU
Lights
Not Installed
Installed
H
(page 6 of 7)
D
E
F
G
8/03 revised 7/13 Form No. 56040800 REV D