5
See Figure 2. Drain the Recovery Tank (L) and disconnect the squeegee hose from the tank. Release the Latch (1) and tilt the tank out and
disconnect the vacuum motor harness connector from the main harness. Disconnect the Cable Assembly (2) from the Recovery Tank (L) and lift
the tank up and off the Tank Pivots (3) and set aside. NOTE: The back-up alarm will be mounted using pre-drilled holes.
6
Mount the Back-Up Alarm (A) to the frame as shown using Screws (D) and Washers (F).
7
Locate the Connector from the main harness that will be located near the mounting location of the Back-up Alarm (A). The connector will have
one GRN/BRN and one GRAY wire going to it. Remove the plug from the connector and Plug the alarm harness into this connector.
8
Proceed to the next page for programming to recognize this kit. After programming, re-install the Recovery Tank (L) and reconnect the Cable
Assembly (2). Reconnect the vacuum motor harness connector to the main harness before latching the tank in the closed position. Reconnect
the squeegee hose to the Recovery Tank (L). Start the machine and test the back-up alarm for proper operation.
The alarm should sound in reverse only.