Back-up alarm kit

Advertisement

WARNING!
TURN KEY OFF BEFORE SERVICING.
5
See Figure 5. Open the engine cover and locate the part of the frame where the back-up alarm will mount using the pre-drilled holes. NOTE:
The backup alarm mounts just to the right of the hydraulic manifold.
6
Mount the Back-Up Alarm (A) to the frame as shown using Screws (D) and Washers (F).
7
Locate the Wire Connector from the main wiring harness next to the hydraulic reservoir. The connector will have one GRN/BRN and one BLU/
BLK wire going to it. Plug in the alarm harness to this connector.
8
Proceed to Page 6 for programming instructions. After programming,
close the engine cover. Start the machine and test the back-up alarm
for proper operation.
The alarm should sound in reverse only.
FIGURE 5
© 2013 Nilfi sk-Advance, Inc.
SC8000 INSTALLATION INSTRUCTIONS
D
(page 5 of 7)
A
F
8/03 revised 7/13 Form No. 56040800 REV D