Symbol Glossary - Philips Willis the Whale Manual

Compressor nebulizer system
Table of Contents

Advertisement

Available languages

Available languages

Class II device, type BF device (device with specific protection against electrical hazards)
DOUBLE INSULATED.
The nebulizer mouthpiece, nebulizer medication cup, nebulizer tubing, mask (if used) and On/Off switch are
applied parts.

Symbol glossary

l
ON (power)
CAUTION/WARNING
O
OFF (power)
Alternating current
Follow instructions for use
Serial number
Atmospheric pressure
Humidity
Type BF applied parts
IP21 Housing Ingress Protection rate: IP21 (protected from the penetration of solid bodies with dimensions
greater than 12 mm. Protected from the penetration of vertically falling water drops).
Warranty
Philips Respironics Inc warrants the Willis the Whale compressor nebulizer system to be free from
defects in materials and workmanship under normal use and operation for a period of 5 years from
date of purchase from Philips Respironics Inc. The warranty is limited to repair or replacement, at Philips
Respironics Inc sole option, of any such component or equipment claimed to be defective when claim
is shown to be bona fide by evaluation by Philips Respironics Inc. This warranty does not extend to any
components or equipment subjected to misuse, improper operation, accidental damage, or unauthorized
repairs, and is not extended to charges of, or for, labor repairs. All items returned must be properly
packaged and shipped, prepaid, by the distributor servicing the unit. Philips Respironics Inc shall not be
liable to purchaser or others for loss of use of equipment or for indirect, or incidental or consequential
damages that might arise.
10
Instructions for use
1. According to the EMC information provided in this document;
2. Portable and mobile RF communications equipment can affect Willis the Whale compressor
nebulizer system.
3. May result in increased EMISSIONS or decreased IMMUNITY of Willis the Whale compressor
nebulizer system.
4. Warning that Willis the Whale compressor nebulizer system should not be used adjacent to or stacked
with other equipment.
Class II, double insulated
5.
Direct current
Guidance and manufacturer's declaration – electromagnetic emissions
Indoor use only
Willis the Whale compressor nebulizer system is compliant for each EMISSIONS test specified by the
standard, e.g. EMISSIONS class and group.
Temperature limitation
Emissions
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC61000-3-3
Compliance
Electromagnetic environment –
guidance
Group 1
Willis the Whale compressor
nebulizer system uses RF energy
only for its internal function.
Therefore, its RF emissions are very
low and are not likely to cause any
interference in nearby electronic
equipment.
Willis the Whale compressor
Class B
nebulizer system is suitable for
use in all establishments, including
domestic establishments and those
Not applicable
directly connected to the public
low-voltage power supply network
that supplies buildings used for
Not applicable
domestic purposes
ENGLISH