Nice MORX Installation Instructions Manual page 26

Control access system
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Table "C15"
Load the operations counter of a combination
Each combination is associated with a counter that subtracts 1 from an initial value
every time the combination is used; when the counter reaches zero the combination is
deactivated. The maximum value of the counter is 999, higher values mean unlimited
operations. At the outset, all the combinations have unlimited operations.
1.
Enter the programming password
2.
Press
to confirm the password
3.
Enter
to select the operation
4.
Press
to confirm
5.
Enter the combination for which the operations counter is required to be reloaded
6.
Press
to confirm
7.
Enter the combination to be reloaded a second time
8.
Press
to confirm
9.
Enter the value to which the counter is required to be loaded
10.
Press
to confirm
N.B.: If the operation was successful 3 tones will be heard
Table "C16"
Programme output
This procedure associates the TIMER function with output N° 1, so that after
it is activated, the output remains so for the pre-set time (minimum 0.5, maximum
6500 seconds). Set the time to 0 seconds to return to the MOMENTARY mode
1.
Enter the programming password
2.
Press
to confirm the password
3.
Enter
to select the operation
4.
Press
to confirm
5.
Enter the value of the timer expressed in tenths of seconds ( maximum value: 65,000)
6.
Press
to confirm
N.B.: If the operation was successful 3 tones will be heard
(Relay 1) in the TIMER mode
Example
GB
1234
1234
450
Example
250
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

MomMotMocard

Table of Contents