7.4 Parameter setting command
No.
Item
Fixed 0xC0 or 0xC2, it means this frame data is control
0
HEAD
command
1
ADDH
High address byte of module(default 00H)
2
ADDL
Low address byte of module (default 0H)
Rate parameters, including serial rate and air rate
7,6:
-------------------------------------------------
5,4,3
3
SPED
-------------------------------------------------
2,1,0
7,,6,5,4,3,2,1,0 Communication channel
Communication frequency (410M + CHAN * 0.5M)
4
CHAN
(Default 0x2E: 433M)
7,
MODBUS)
5
OPTION
-------------------------------------------------
6,5,4,3,2 Reserved bit, write 0
-------------------------------------------------
1, 0
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd.
Description
Serial parity bit
00:8N1(default)
01:8O1
10:8E1
11:8N1
TTL serial speed (bps)
000: Serial baud rate is 1200
001: The serial port baud rate is 2400
010: The serial port baud rate is 4800
011: Serial baud rate is 9600 (default)
100: The serial port baud rate is 19200
101: Serial baud rate is 38400
110: Serial baud rate is 57600
111: Serial baud rate is 115200
Wireless air data rate (bps)
000:Air data rate is 1.2k
001:Air data rate is 2.4k(default)
010:Air data rate is 4.8k
011:Air data rate is 9.6k
100:Air data rate is 19.2k
101:Air data rate is 50k
110:Air data rate is 100k
111:Air data rate is 200k
Fixed transmission enabling bit(similar to
0: Transparent transmission mode
1: Fixed transmission mode
Transmission power (approximation)
E49-400T20D User Manual
Remark
Must be 0xC0 or 0xC2
C0: Save the parameters when power off
C2: Do not save the parameters when power
off
00H-FFH
00H-FFH
----------------------------------------
UART baud rate can be different between
communication parties
The UART baud rate has nothing to do with
wireless transmission parameters & won't
affect the wireless transmit / receive
features.
----------------------------------------
----------------------------------------
The lower the air data rate, the longer
the
transmitting
distance,
anti-interference
performance
longer transmitting time
The air data rate must keep the same
for both communication parties.
----------------------------------------
00H-C8H,
correspond to 410~510 MHz
In fixed transmission mode, the first
three bytes of each user's data frame
can be used as high/low address and
channel. The module changes its
address and channel when transmit.
And it will revert to original setting
after complete the process.
----------------------------------------
better
and
14