5.2.3 Reset and exit sleep mode

Only when resetting and exiting sleep mod

5.3.4 Notes for AUX

The function 1 and function 2 mentioned above have low output priority, that is, if any output low condition is met,
AUX outputs a low level; when all low level conditions are not met, AUX outputs a high level.
When the AUX output is low, it indicates that the module is busy, and the operating mode detection will not be
performed; when the AUX output is high, the mode switching will be completed.
When users enter other modes from mode 3 (sleep mode) or during the reset process, the module will reset user
parameters, during which AUX outputs low level.

5.3.5 Fixed-point mode description