5. Function description

5.1 Module reset

When the module is powered on, AUX outputs low level immediately, conducts hardware self-check and sets the
operating mode based on user's parameters. During the process, the AUX remains low level. After the process completed,
the AUX outputs high level and starts to work as the operating mode combined by M1 and M0. Therefore, users need to
wait the AUX rising edge as the start of module's normal work.

5.2 AUX description

AUX P is used as indication for wireless sending & receiving buffer and self-check.
It can indicate whether there are data that are not sent yet via wireless way, or whether all wireless data has been
sent through UART, or whether the module is still in the process of self-check initialization.

5.2.1 Wireless receiving indication

After receiving the valid wireless data, the module will immediately pull AUX low and start UART to output data
and then pull up AUX after the data output is completed.

5.2.2 Wireless transmission indication

After receiving the serial port data, the module will immediately pull down AUX and start sending data wirelessly
and after all the data is sent, pull up AUX.