C4+C4+C4

7.5 Parameter setting command

No.
Item
Fix 0xC0 or 0xC2, it means this frame data is
control command
0
HEAD
High address byte of module
1
ADDH
(the default 00H)
Low address byte of module
2
ADDL
(the default 00H)
3
SPED
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
In sleep mode(M0=1,M1=1),
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time. During
the reset process, the module will conduct self-check, AUX outputs low level. After reset completing,
the AUX outputs high level, then the module starts to work regularly which the working mode can be
switched or be given another instruction.
Description
7
6
0
0
0
1
1
0
1
1
5
4
3
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
2
1
0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
C0: Save the parameters when power-down
C2: Do not save the parameters when power-down
00H-FFH
00H-FFH
UART parity bit
8N1 (default)
8O1
8 E1
8N1 (equal to 00)
TTL UART baud rate(bps)
1200
2400
4800
9600 (default)
19200
38400
57600
115200
Air data rate(bps)
0.3k
1.2k
2.4k (default)
4.8k
9.6k
19.2k
E32-433T33S user manual
Remark
Must be 0xC0 or 0xC2
UART mode can be different between
communication parties
UART baud rate can be different
between communication parties
The UART baud rate has nothing to do
with wireless transmission parameters &
won't affect the wireless transmit /
receive features.
The lower the air data rate, the longer
the
transmitting
anti-interference performance and longer
transmitting time
The air data rate must keep the same for
both communication parties.
distance,
better
14