Terminal Block Connector Pin out
A second power supply +VinB can be fitted as a back-up to the main power supply +VinA to prevent
down time should one power source fail.
*Func Ground – Functional ground is a connection to the ground from the DIN rail.
Pin 1
RS-232
Sig GND
RS-485 FD
Sig GND
RS-485 HD
Sig GND
Power Input
Power GND
Reset Button
Manual Reboot
1) Press the reset button once.
2) The status LED will flash and after 5 seconds the device will reboot.
3) When the device is restarted, any connections you have had to the COM ports will need to be
re-established.
Manual Hard Restore
1) Press and hold the reset button on the device for 5 seconds.
2) The status LED will flash red/green and the device will be restored to factory default settings.
For the factory settings, see Factory Default Settings section.
Storage and Operating Environment Guidelines
Operating Temperature: -30
Storage Temperature: -50
Humidity: 5% to 95% non-condensing
Housing: IP-30 rated non-conducting polyamide case with integrated DIN rail mount
Factory Default Settings
Device Network IP Address
Web Server Port
Port Mode
Baud rate
Databits
Stop bits
Parity
Flow Control
Duplex mode
Protocol Settings
ES Industrial Range
Product Manual V3.3
Pin 2
CTS
RxD-
+Vin A
o
o
C to +80
C
o
o
C to +150
C
Network Settings
DHCP Mode
80
Port Settings
RS-422
115200
8
N
1
None
Full Duplex
Telnet Mode (Server)
© Copyright Brainboxes Ltd
Pin 3
Pin 4
RxD
RTS
RxD+
TxD+
Data+
+Vin B
Power GND
Pin 5
TxD
TxD-
Data-
Func GND*
Page 11 of 53