Water Connection - Fagor Advance Plus APG-061 Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
INSTALLATION MANUAL ADVANCE PLUS
ENGLISH

WATER CONNECTION

3/4"
3/4"
A
B
C
D
The water used should have the following properties:
PH 6.5÷7.5
Chlorides < 150mg/litre
Chlorine concentration 0.2÷0.5 mg/litre
Conductivity 400÷2000 µS
Water impurities Ø < 0.08 mm
Water hardness 5-10ºF
Recommended filters:
A) Fine filter.
If the water contains impurities such as sand, iron particles or floating
substances, we recommend the use of a fine filter at the water input.
B) Activated carbon filter.
If the water has a high chlorine content over 0.2 mg/l (ppm) (this information can
be obtained from the relevant water board), an activated carbon filter should be
installed.
C) Installation of osmosis recirculation.
When the chloride concentration is above 150 mg/l (ppm) (this information can be
obtained from the relevant water board), an osmosis recirculation installation should be
mounted. In this case, please remember that the minimum conductivity value is 400
µS/cm.
D) Water descaling:
For water with a high level of limescale (without chloride load) the water should be
treated. Systems: H+. Interchange of ions or Kleensteam. We strongly advise against
the use of sodium exchangers (normally used in dish washers) due to the formation of
sodium sediment and the delay in boiling with common salt.
We recommend the manufacturer, Britta, for the selection of filter systems (A, B, C, D).
Warning
Before connection, look at the label that shows which is the water inlet.
1
300kPa
R3/4"
Manguera entrada agua
Water inlet hose fIG 12
29
Only connect drinking water to the
appliance.
Connect the appliance to the mains
water supply at point 1 (fig 12)using the
hose supplied.
The pressure of the incoming water
should be between 400 and 400 kPa
2
(2-4 kg/mm
). We recommend 250 kPa.