Option Ii. Flatcable Connection; Figure 2-4 Option I - Transition Module - Brand Innovations BI-0316 Technical Manual

Mass storage module
Table of Contents

Advertisement

Functional Description
The BI-0318 and BI-0319 are modules that fit on the VMEbus P2 connector of the BI-0316. They route
the SCSI signals of the VMEbus P2 connector to standard SCSI-2 and SCSI-3 connectors. The
BI-0318 and BI-0319 serve several functions:
enable daisy-chaining of the SCSI-2 and SCSI-3 cables
allowing external termination
support mixing of 8- and 16-bit cables
The BI-0318 and BI-0319 Transition Modules can be used in VMEbus systems that are fitted with or
without a J2 backplane. In either case the BI-0318 and BI-0319 provide universal solutions with their
SCSI-2 and SCSI-3 type of connectors. See the Technical Manual of the BI-0318 and BI-0319 for the
installation details.
2.6.2

Option II. Flatcable Connection

This option can be used when the SCSI host module has a VMEbus P2 pin layout compatible with the
BI-0316.