System Set-Up
Summary
• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Test
Test Run
3 Minutes Delay
Remote sensor active
Temp. sensor selection
Dry Contact Mode
Central Control Address
Override Master/Slave
Pump test run
Air cooling set temp.
Water cooling set temp.
Air heating set temp.
Water heating set temp.
DHW set temp.
Cooling / Heating only mode
Water supply off temp. during cooling
Outdoor temp. for auto mode
Indoor air temp. for auto mode
LWT for auto mode
Tank disinfection setting 1
Tank disinfection setting 2
Tank setting1
Tank setting2
DHW time setting
Night time power setting
TH on/off Variable, heating air
TH on/off Variable, heating water
TH on/off Variable, cooling air
TH on/off Variable, cooling water
TH on/off Variable, DHW
Heating temp. setting
Cooling temp. setting
Pump setting in heating
Pump setting in cooling
Forced operation
48 Hydro Kit
Checking whenever Amount of refrigerant is normal
Factory use only
Connection information about remote air sensor
Selection for setting temperature as air temperature or leaving water temperature
Setting dry contact auto start option.
When Central Controller is installed, address assigning is set by this function.
Override master/slave selection function is to prevent the unit's different mode
operation. If the unit is set as the slave, it blocks a change of opposite operating
mode(cooling/heating).
Checking whether water circulation is normal.
Adjusting range of 'Setting Air Temperature' in cooling mode
Adjusting range of 'Setting Leaving Water Temperature' in cooling mode
Adjusting range of 'Setting Air Temperature' in heating mode
Adjusting range of 'Setting Heating Flow Temperature' in heating mode
Adjusting range of 'Setting DHW tank Heating Flow Temperature' in domestic hot
water tank heating mode
Setting the Operation mode lock
Determine leaving water temperature when the unit is turned off. This funtion is
used for preventing condensation on the floor in cooling mode
Setting outdoor Min/Max temperature for auto mode
Setting indoor Min/Max temperature for auto mode
Setting heating flow Min/Max temperature for auto mode
Setting start/maintain time for pasteurisation
Setting pasteurisation temperature
Setting start temperature for operation
Setting maintain temperature for operation
Determine follow time duration : operation time of domestic hot water tank heating,
stop time of domestic hot water tank heating, and delay time of DHW tank heater
operating
Setting to distinguish power-on time type of model using night power
Setting Thermal on/off Air Temperature gap in heating mode
Setting Thermal on/off Water Temperature gap in heating mode
Setting the step value to adjust air temperature gap in cooling mode
Setting the step value to adjust water temperature gap in cooling mode
Setting the step value to adjust DHW temperature gap in heating mode
Setting the temperature of entering or leaving water in heating mode
Setting the temperature of entering or leaving water in cooling mode
Setting options of water pump operation / delay time in heating mode
Setting options of water pump operation / delay time in cooling mode
Setting of Forced product operation