MAINTENANCE
MAIN BROOM (Refer to the Main Broom Group and Main
Broom Lift Group in the Parts section)
FOR SAFETY: The main broom and the vacuum impeller
automatically begin to operate when the main broom lever is
positioned in the forward end of its slot.
The main broom spans the width of the machine, and
sweeps debris into the hopper. Inspect the main broom daily
for wear or damage. Remove any obstructions found in the
main broom chamber, main broom drive hub or idler hub.
The main broom should be replaced when the remaining
bristles measure 5/8 " (16mm) or less in length.
NOTE: All original equipment brooms are equipped with
"Perform Alert™". This feature tells the operator when it is
time to replace the main broom. "Perform Alert™" brooms
have bright yellow tufts located on each end of the broom.
These tufts are pre-trimmed to indicate the length of a worn
out broom. When the main body of the broom wears to a
length that matches the yellow tufts, the broom should be
replaced.
Always check the main broom pattern when installing a new
broom.
TO REMOVE THE MAIN BROOM
1. Turn off machine and set parking brake.
FOR SAFETY: Before leaving or servicing the machine, stop
on a level surface, apply parking brake, turn off the machine
and remove key.
2. Raise rear cover.
3. Disconnect batteries from machine.
4. Lower the main broom lever.
5. Open the right side broom door.
6. Remove the idler arm D-ring retainer.
7. Remove the main broom idler arm.
8. Grasp the broom by the core and remove.
4-7
QTFSB 98351 04/25/03
TO INSTALL THE MAIN BROOM
1. Turn off machine and set parking brake.
FOR SAFETY: Before leaving or servicing
the machine, stop on level surface, apply
parking brake, turn off machine and remove
key.
2. Raise rear cover.
3. Disconnect batteries from machine.
4. Lower the main broom lever.
5. Open the right side broom door.
6. If replacing a worn broom, turn the main
broom adjustment knob so that the
broom drive hub is raised to a position
that will allow a new broom to easily
slide onto the broom drive hub.
7. Slide the new brush into the broom
chamber.
8. Hold the broom by the core and rotate
the broom counter-clockwise while
pushing the broom onto the drive hub.
Make sure that the broom is fully seated
onto the drive hub before attempting to
install the idler arm.
9. Locate the idler arm. Align the tabs on
the idler hub with the slots on the main
broom core. Slide the idler into the main
broom core, the position the upper right
end of the idler arm onto the two locator
pins.
10. Replace and tighten the D-ring retainer.
11. Close the broom door.
12. Check the main broom floor pattern and
adjust as necessary.

Advertisement