Siemens 7XV5655-0BB00 Manual page 49

Modem for transmission of serial data or protocols from devices with an rs232/rs485/fo interface via ethernet
Hide thumbs Also See for 7XV5655-0BB00:
Table of Contents

Advertisement

English
Activates/deactivates modem echo.
ATQ
ATQ0 send echo
ATQ1 no echo
Valid IP addresses for call accept.
ATR
ATRnumber=value
ATR2=192.168.120.23
ATR2? read out register
Ten IP addresses, for which calls are accepted, can be defined in the password
configuration mode (registers 110-119).
If this list is empty, calls are accepted from any remote modem.
If a call is not accepted by a modem the "ACCESS DENIED" message is output.
Sets and queries the internal modem registers.
ATS
ATSregister=value Sets the register
Example:
ATSregister?
Example:
Returns system echo of modem as character string or digits.
ATV
ATV0 response is a number
ATV1 response is a character string ("Ring", "Connect", "Busy")
See also section "Result Codes".
49 / 77
ATS0=1 modem answers a call after 1 ring.
Queries the register:
ATS0? (output "+" default setting)
(number = 0-9)
(see also AT&R)