8 Troubleshooting
Malfunction
The system operates,
▪ Check the airflow rate setting. Refer to
but cooling or heating
"5.4 Airflow rate" on
is insufficient.
▪ Check the temperature setting. Refer to
"5.3.1  To start/stop operation mode and
to set the temperature" on
▪ Check if the airflow direction setting is
appropriate.
direction" on
▪ Check if the air inlet or outlet of the
outdoor or indoor unit is NOT blocked by
obstacles. Remove any obstacles and
make sure the air can flow freely.
▪ Check if the air filters are clogged. Clean
the air filters. Refer to
and service" on
▪ Check for open doors or windows. Close
doors and windows to prevent wind from
coming in.
▪ Check if the unit operates in Econo or
Outdoor unit quiet operation. Refer to
"5.8  Econo and Outdoor unit quiet
operation" on
▪ Check if there is any furniture directly
under or next to the indoor unit. Move the
furniture.
The system operates,
▪ The air conditioner may be warming up
but heating is
for heating operation. Wait for 1 to 4
insufficient (air is NOT
minutes.
blown from the unit).
▪ If a flowing sound is heard, the outdoor
unit may be in defrost operation. Wait for
4 to 12 minutes.
The front panel does
Check for the obstacles and try to open the
NOT open.
front panel using the user interface. Refer
to
"7.4 To open the front panel" on
The ON/OFF timer
▪ Check if the Weekly timer and ON/OFF
does NOT operate
timer are set to the same time. Change
according to the
or deactivate the setting. Refer to
settings.
"5.10  OFF/ON
page  11
operation" on
▪ Check if the clock and the day of the
week
"4.4 About the clock" on
Heating operation
Check if the user interface's jumper J8 has
CANNOT be selected.
NOT been cut.
An abnormal function
The air conditioner may malfunction
happens during
because of lightning or radio waves. Turn
operation.
the breaker OFF and back ON.
The unit does NOT
▪ Check the batteries of the user interface.
receive signals from
Refer to
the user interface.
page 6.
▪ Make sure that the transmitter is NOT
exposed to direct sunlight.
▪ Check if there are any electronic starter
type fluorescent lamps in the room.
Contact your dealer.
The user interface
Replace the batteries of the user interface.
display is blank.
User reference guide
20
Measure
page 8.
page 8.
Refer
to
"5.5  Airflow
page 8.
"7  Maintenance
page 16.
page 10.
page 17.
timer
operation"  on
and
"5.11  Weekly
timer
page 12.
are
set
correctly.
Refer
to
page 6.
J8
"4.3  To insert the batteries"  on
Malfunction
An error code is
Consult your local dealer. Refer to
displayed on the user
"8.2 Solving problems based on error
interface.
codes" on page 21
error codes.
Other electric
If the user interface signals operate other
appliances start to
electric appliances, move the other
operate.
appliances away, and contact your dealer.
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
8.1
Symptoms that are NOT system
malfunctions
The following symptoms are NOT system malfunctions:
8.1.1
Symptom: A sound like water flowing is
heard
▪ This sound is caused by the refrigerant flowing in the unit.
▪ This sound may be generated when water is flowing away from
the unit during cooling or drying operation.
8.1.2

Symptom: A blowing sound is heard

This sound is generated when the direction of the refrigerant flow is
changed (e.g. when switching from cooling to heating).
8.1.3

Symptom: A ticking sound is heard

This sound is generated when the unit slightly expands or contracts
with changes in temperature.
8.1.4

Symptom: A whistling sound is heard

This sound is generated by the refrigerant flowing during defrost
operation.
8.1.5
Symptom: A clicking sound during
operation or idle time is heard
This sound is generated when the refrigerant control valves or
electrical parts operate.
8.1.6

Symptom: A clapping sound is heard

This sound is generated when an external device sucks air out of the
room (e.g. exhaust fan, extractor hood) while the doors and windows
in the room are closed. Open the doors or windows, or turn off the
device.
8.1.7
Symptom: White mist comes out of a unit
(Indoor unit, outdoor unit)
When the system is changed over to heating operation after defrost
operation. Moisture generated by defrost becomes steam and is
exhausted.
8.1.8

Symptom: The units can give off odours

The unit can absorb the smell of rooms, furniture, cigarettes, etc.,
and then emit it again.
Measure