Step 9: Mounting Antenna to Mast
A. Loosen nuts on the main boom and brace mast clamps.
B. Slide both mast clamps over the mast pointing the front of
the antenna (small end) towards stations and tighten the
boom brace mast clamp securely.
C.Let the main boom mast clamp slide down the mast until the
boom brace supports the main boom.
D. Tighten the main boom mast clamp securely. (see Figure 8)
Step 10: The 75 ohm coaxial cable downlead may be secured
to the mast by either taping it or use of plastic wire ties.
HOW TO PROVIDE LIGHTNING
PROTECTION FOR TV ANTENNA
AND SET
Step 1. Mount the grounding block as close as possible to
where the 75 ohm coaxial cable (lead-in) enters the house.
See Figure 9.
Step 2. The ground wires for both the
mast and the lead-in should be copper or aluminum wire, num-
ber eight (8) or larger. See Figure 9.
Step 3. The lead-in wire from the antenna to the ground-
ing block and the mast ground wire should be secured to the
house, spaced from four (4) or six (6)
feet apart. See Figure 9.
NOTE: In the case of a "ground up" antenna installation, it may
not be necessary to ground the mast if the mast extends four
or moure feet into the earth. Consult a TV serviceman for the
proper depth in your location.
90 DAY LIMITED WARRANTY
Winegard Company warrants this Winegard product against any defects in materials or workmanship within 90 (ninety) days from date of purchase.
No warranty claim will be honored unless at the time the claim is made, you present proof of purchase to an authorized Winegard dealer (if unknown,
please contact Winegard Company, 3000 Kirkwood Street, Burlington, IA 52601-2000, Telephone 800-288-8094).
Winegard Company (at its option) will either repair or replace the defective product at no charge to you. This warranty covers parts, but does not cover
any costs incurred in removal, shipping or reinstallation of the product. This limited warranty does not apply if the product is damaged, deteriorates,
malfunctions or fails from: misuse, improper installation, abuse, neglect, accident, tampering, modification of the product as originally manufactured
by Winegard, usage not in accordance with product instructions or acts of nature such as damage caused by wind, lightning, ice or corrosive environ-
ments such as salt spray and acid rain.
The 90 Day Warranty is provided on the condition that the equipment is properly delivered with all handling and freight charges prepaid to your Win-
egard dealer for return to our factory for repair or replacement. Winegard dealers will arrange for the replacement or repair and return to you without
charge the product which failed due to defective material or workmanship.
WINEGARD COMPANY WILL NOT ASSUME ANY LIABILITIES FOR ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, MADE BY ANY
OTHER PERSON.
ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE AND MERCHANTABILITY ARE LIMITED TO THE 90-DAY PERIOD OF THIS WARRANTY.
The foregoing shall be the sole and exclusive remedy of any person, whether in contract, tort or otherwise, and Winegard shall not be liable for
incidental or consequential damage or commercial loss, or from any other loss or damage except as set forth above.
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion of limitation of incidental or consequential damages, so
the above limitations or exclusions may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Printed in U.S.A. © Winegard Company 2007 1450292 Rev. 10/08
MAST CLAMP
Fig. 8
HEX NUT
MAST CLAMP
INSERT
U-BOLT
MASTING
2" OD MAX.
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
Fig. 9
Antenna Lead
In Wire
Antenna Mast
Ground
Clamp
Electric
Service
Antenna
Equipment
Discharge Unit
(NEC Section 810-21)
Grounding Conductor
(NEC Art 250, Part H)
Ground
Clamps
Power Service Grounding
Electrode System
(NEC Art 250, Part H)
NEC - National Electrical Code
Rev. 2/08
Platinum Series/Ultimate Series
Digital/High Definition
INSTRUCTIONS
VHF/UHF MODELS
HD7698P & HD8200U
WARNING
INSTALLATION OF THIS ANTENNA NEAR POWER LINES IS DANGEROUS.
FOR YOUR SAFETY, FOLLOW THE INSTALLATION INSTRUCTIONS.
NOTE
To prevent damage in shipping, the second set of elements from the rear of the boom are folded to the
reverse side. You can identify these elements by the tags attached to them. Follow the directions on the
tags carefully.
Winegard Company • 3000 Kirkwood Street • Burlington, IA 52601-2000
VHF/UHF
MODEL HD7698P
VHF/UHF
MODEL HD8200U

Advertisement

loading

Summary of Contents for Winegard Platinum Series/

  • Page 1 Winegard Company warrants this Winegard product against any defects in materials or workmanship within 90 (ninety) days from date of purchase. No warranty claim will be honored unless at the time the claim is made, you present proof of purchase to an authorized Winegard dealer (if unknown, VHF/UHF please contact Winegard Company, 3000 Kirkwood Street, Burlington, IA 52601-2000, Telephone 800-288-8094).
  • Page 2 Step 1: Contents of Package Parts List Quantity A. Remove all parts from the box and compare to the parts list to ensure Fig. 2 Rear Section (section with longest elements) nothing is missing and to become familiar with the part names. REMOVE BOLT AND HEX NUT AND Front Section (section with shortest elements) SLIDE SWEDGE UNTIL IT LINES UP...

This manual is also suitable for:

Ultimate seriesHd7698pHd8200u