  • Page 1 ITC237-PW1A-IRZ User’s Manual Version 1.0.0...
  • Page 2 Welcome Thank you for purchasing our HD intelligent traffic camera! This user’s manual is designed to be a reference tool for your system. Please read the following safeguard and warnings carefully before you use this series product! Please keep this user’s manual well for future reference!
  • Page 3 Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited power source is rated 90-240V. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation.
  • Page 4 7.Daily Maintenance Please shut down the device and then unplug the power cable before you begin daily maintenance work. Use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device.
  • Page 5: Table Of Contents

    Table of Contents General Introduction ...................... 1 Overview ......................1 Features ......................1 Framework........................3 Appearance ....................... 3 Cable Structure ....................3 2.2.1 Combination Cable ..................3 Cable Installation ......................5 System Network ......................6 Web Operation ......................7 Network Connection ..................7 Login and Main Interface ...................
  • Page 6: General Introduction

    1 General Introduction 1.1 Overview This product is a snapshot camera for parking lot. It has advanced vehicle detection and recognition technologies to snapshot vehicle, plate which co-operate with rear-end server and AUX device to manage entrance/exit and spots in parking lot. This product is applied to parking lot management system.
  • Page 7 outdoor environment.  System can automatically set shutter speed and iris value according to Auto the snapshot video exposure condition. Exposure  To output the standard video signal in the different illumination environments, the amplifier needs to adjust in a wide range. The system Auto Gain can enhance the camera sensitivity in low illumination and enhance the video signal output to get the clear and high definition video.
  • Page 8: Framework

    2 Framework 2.1 Appearance Figure 2- 1 Figure 2- 2 2.2 Cable Structure 2.2.1 Combination Cable See Figure 2- 3 .
  • Page 9 Figure 2- 3 Port Function ① Audio Out Audio output port Output audio signal (not available) ② Audio In Audio input port Input audio signal (not available) ③ Network port Connect to Ethernet. ALARM_NO Alarm output port Output alarm signal ALARM_COM ④...
  • Page 10: Cable Installation

    3 Cable Installation Figure 3- 1 Device cable installation is shown in Figure 3- 1 Step 1. Use a small straight screwdriver to unfasten the screw on cable slot by counterclockwise rotation. Step 2. Insert cable to corresponding slot. Step 3. Fasten the screw with straight screwdriver by clockwise rotation. Note: If you want to remove cable, please unfasten the screw on cable slot by counterclockwise rotation, and pull out cable.
  • Page 11: System Network

    4 System Network Please refer to Figure for system connection. Figure 4-1...
  • Page 12: Web Operation

    5 Web Operation This series HD intelligent traffic camera product supports the Web access and management via Web client end includes several modules: monitor channel list, record search, alarm setup and etc. 5.1 Network Connection Please follow the steps listed below for network connection. ...
  • Page 13 Figure 5- 2 Figure 5- 3 After installation, the interface is shown as below. See Step 3. Please input your user name and password. Default factory name is admin and password is admin. Figure 5- 3 Figure 5- 4 After you logged in, you can see the main window. See...
  • Page 14 Figure 5- 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction.
  • Page 15: Quick Configuration Tool

    6 Quick Configuration Tool 6.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 6.2 Operation Step 1.
  • Page 16 Figure 6- 2 Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 6- 3 Figure 6- 3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set.
  • Page 17 Figure 6- 4 Figure 6- 5 After you logged in, the configuration tool main interface is shown as below. See Figure 6- 5 For detailed information and operation instruction of the quick configuration tool, please refer to the Quick Configuration Tool User’s Manual included in the resources CD.
  • Page 18: Technical Specification

    7 Technical Specification Parameter Type Parameter Name Value Model ITC237-PW1A-IRZ Sensor 1/1.9 inch CMOS Shutter 1/12.5~1/10000,manual or auto 0.002Lux/F1.2(color mode),0.0002Lux/F1.2 Min Illumination (black white mode) Scan Progressive Day/Night Mode Switch IR-CUT motorized cut Camera Support full auto, customized range auto and...
  • Page 19 Parameter Type Parameter Name Value Power Sync Support Consumption <15W ﹣30℃~﹢60℃ Temperature Protection Level IP66 ≤95% Humidity Dimension(mm) 94.92mmX94.92mmX272.90mm Weight 1.4kg...
  • Page 20: Faq

    8 FAQ I cannot boot up Please click RESET button for at least five seconds to restore the device. factory default setup. I cannot upgrade The status indication light is shown as red when network upgrade device operation failed. You can use port 3800 to continue upgrade. network.