Available languages

Pattern
MODEL
TYPE
MTPGHV13
MTPGHV15
GRAVITY
MTPGHV17
MTPGHV19
Note: Atomizing (dynamic) air pressure is measured and regulated by an air control meter at gun
inlet when the triggeris pulled
AIR INLET IS 1/4" PF/ NPS (M)
MTPGHV13
MODEL:
MTPGHV15
MTPGHV17
MTPGHV19
TROUBLE SHOOTING
Cause
• Uneven air pressure from side-holes
due to dried material
• Dried material clogging around the tip
of fluid nozzle, at the center hole,
reduces atomization
• It may also be caused
by loose fluid nozzle
• Atomizing air pressure is too high
• Fluid output is too high
• Paint viscosity is too low
• Atomizing air pressure is too low
• Fluid output is too low
• Paint viscosity is too high
• Air enters the fluid passageway due to
the
needle packing set drying out
• Dirt between fluid nozzle and gun body
or
osely installed fluid nozzle.
lo
• A loose or defective in Swivel nut on
the cup or material hose
• Fluid nozzle and fluid needle set are
not seated properly
• The first stage travel or trigger
decreases. (when only air discharges)
• Paint build-up inside air cap
STAINLESS STEEL
ATOMIZING
FLUID NOZZLE TIP
AIR PRESSURE
mm / inch
kgf/cm
1.3 / 0.051
1.5 / 0.059
2.0 / 29
1.7 / 0.067
1.9 / 0.075
FLUID INLET IS M 16 X P1.5
1.3 mm
Product Type:
1.5 mm
GRAVITY FEED HVLP
1.7 mm
SPRAY GUN
1.9 mm
• Use a thinner to dissolve obstructions;
blow the gun clean afterwards
• Clean the nozzle tip by using
a rag wet with thinner
• Tighten up the fluid Nozzle
• Reduce air pressure
• Reduce fluid flow by turning fluid
screw right and adjusting spray width adjustment
• Increase viscosity by adding more paint
• Increase air pressure
• Increase fluid flow by turning fluid control screw
left and adjusting spray width adjustment
• Reduce viscosity of paint
• Unscrew the needle packing set and lubricate
the needle packing set
• Clean the fluid nozzle and fluid nozzle seat in
the gun body by using a rag wet with thinner
• Tighten or replace the swivel nut
• Clean or replace fluid nozzle and fluid needle set
• Replace fluid nozzle and fluid needle set
• Clear air cap
AIR
CONSUMPTION
OUTPUT
/min / cfm
2
/ psi
m
286 / 10.1
288 / 10.2
ALL ABOVE RECORDS FOR REFERENCE ONLY.
Page 4
Correction
control
FLUID
PATTERN
COMPRESSOR
WIDTH

/ min
mm /inch
KW
190
230 / 9.1
210
235 / 9.3
0.75 ~1.5
225
245/ 9.6
240
250 / 9.8
CUP
CAPACITY
0.6 /1.0
(PL/AL)