Siemens SINAMICS G130 TM150 Operating Instructions Manual
Siemens SINAMICS G130 TM150 Operating Instructions Manual

Siemens SINAMICS G130 TM150 Operating Instructions Manual

Terminal module

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SINAMICS G130 TM150

  • Page 3 ___________________ Safety information ___________________ General information ___________________ SINAMICS Mechanical installation ___________________ Electrical installation SINAMICS G130 Terminal Module 150 (TM150) ___________________ Technical specifications Operating Instructions Firmware version V5.1 11/2017 A5E03758735A...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents Safety information ........................... 5 General safety instructions ....................... 5 Handling electrostatic sensitive devices (ESD) ..............10 General information ..........................11 Safety information ........................12 Mechanical installation .......................... 15 Electrical installation..........................17 Overview ..........................17 Interface description ........................ 18 4.2.1 X524 electronics power supply ....................
  • Page 6 Table of contents Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 7: Safety Information

    Safety information General safety instructions WARNING Electric shock and danger to life due to other energy sources Touching live components can result in death or serious injury. • Only work on electrical equipment if you are appropriately qualified. • Always observe the country-specific safety rules for all work. Generally, the following steps apply when establishing safety: 1.
  • Page 8 Safety information 1.1 General safety instructions WARNING Electric shock due to equipment damage Improper handling may cause damage to equipment. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. •...
  • Page 9 • If you come closer than around 2 m to such components, switch off any radio devices or mobile phones. • Use the "SIEMENS Industry Online Support App" only on equipment that has already been switched off. WARNING Motor fire in the event of insulation overload There is a greater load on the motor insulation as result of a ground fault in an IT system.
  • Page 10 Safety information 1.1 General safety instructions WARNING Fire due to inadequate ventilation clearances Inadequate ventilation clearances can cause overheating of components with subsequent fire and smoke. This can cause severe injury or even death. This can also result in increased downtime and reduced service lives for devices/systems. •...
  • Page 11 Safety information 1.1 General safety instructions Note Important safety instructions for Safety Integrated functions If you want to use Safety Integrated functions, you must observe the safety instructions in the Safety Integrated manuals. Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 12: Handling Electrostatic Sensitive Devices (Esd)

    Safety information 1.2 Handling electrostatic sensitive devices (ESD) Handling electrostatic sensitive devices (ESD) Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules or devices that may be damaged by either electric fields or electrostatic discharge. NOTICE Damage through electric fields or electrostatic discharge Electric fields or electrostatic discharge can cause malfunctions through damaged individual components, integrated circuits, modules or devices.
  • Page 13: General Information

    General information The TM150 Terminal Module is a DRIVE-CLiQ component for temperature evaluation. The temperature is measured in a temperature range from -99° C to +250° C for the following temperature sensors: ● PT100 (with monitoring for wire breakage and short-circuit) ●...
  • Page 14: Safety Information

    The use of incorrect or not released DRIVE-CLiQ cables can cause damage or functional faults to devices or the system. • Use only appropriate DRIVE-CLiQ cables that have been released by Siemens for the associated use case. Terminal Module 150 (TM150)
  • Page 15 General information 2.1 Safety information Note Malfunctions due to polluted DRIVE-CLiQ interfaces Malfunctions can occur in the system through the use of polluted DRIVE-CLiQ interfaces. • Cover unused DRIVE-CLiQ interfaces with the supplied blanking covers. Note Function equipotential bonding for distributed DRIVE-CLiQ nodes Integrate all of the components that are connected via DRIVE-CLiQ into the function equipotential bonding concept.
  • Page 16 General information 2.1 Safety information Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 17: Mechanical Installation

    Mechanical installation Figure 3-1 Dimension drawing Terminal Module 150 (TM150) Note Mounting space The TM150 is installed near the Power Module on a mounting rail, which must be provided by the customer. Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 18 Mechanical installation Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 19: Electrical Installation

    Electrical installation Overview Figure 4-1 Terminal Module 150 (TM150) Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 20: Interface Description

    Electrical installation 4.2 Interface description Interface description 4.2.1 X524 electronics power supply Table 4- 1 Terminal strip for the electronic power supply X524 Terminal Designation Technical specifications Power supply Voltage: 24 VDC (20.4 V – 28.8 V) Current consumption (max./typ.): 0.5 A / 0.1 A Power supply max.
  • Page 21: X531-X536 Temperature Sensor Inputs

    Electrical installation 4.2 Interface description 4.2.3 X531-X536 temperature sensor inputs Table 4- 3 X531-X536 temperature sensor inputs Terminal Function Function Technical data 1x2-/2x2-wire 3 and 4-wire +Temp Temperature sensor connection for sensors with (channel x) (Channel x) 1x2 wires Connection of the 2nd measurement cable for sensors with 4 wires -Temp Temperature sensor connection for sensors with...
  • Page 22 Electrical installation 4.2 Interface description NOTICE Damage to motor in the event of incorrectly connected KTY temperature sensor If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect when the motor overheats. Overheating can cause damage to the motor. •...
  • Page 23: Meaning Of The Leds On The Terminal Module Tm150

    Electrical installation 4.3 Connection examples 4.2.4 Meaning of the LEDs on the Terminal Module TM150 Table 4- 5 Description of the LEDs on the TM150 Color State Description READY The electronic power supply is missing or lies outside the permissible tolerance range.
  • Page 24 Electrical installation 4.3 Connection examples Figure 4-3 Connection example for a Terminal Module TM150 Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 25: Protective Conductor Connection And Shield Support

    Electrical installation 4.4 Protective conductor connection and shield support Protective conductor connection and shield support The following diagram shows a typical Weidmüller shield connection clamp for the shield supports. ① Protective conductor connection M4/1.8 Nm ② Shield connection terminal, Weidmüller company, type: KLBÜ CO1, order number: 1753311001 Figure 4-4 Shield support and protective conductor connection of the TM150...
  • Page 26 Electrical installation 4.4 Protective conductor connection and shield support Terminal Module 150 (TM150) Operating Instructions, 11/2017, A5E03758735A...
  • Page 27: Technical Specifications

    Technical specifications General technical data Table 5- 1 General technical data Product standard EN 61800-5-1 Technical data Table 5- 2 Technical data 6SL3055-0AA00-3LA0 Unit Value Electronic power supply Voltage 24 V DC (20.4 – 28.8) Current (without DRIVE-CLiQ) 0.07 Power loss PE/ground connection On housing with M4/1.8 Nm screw Weight...