Rectifying Faults; Warnings - EWM T 4.01 Operating Instructions Manual

Dc comfort 2.0
Hide thumbs Also See for T 4.01:
Table of Contents

Advertisement

Rectifying faults

6
All products are subject to rigorous production checks and final checks. If, despite this, something fails to
work at any time, please check the product using the following flowchart. If none of the fault rectification
procedures described leads to the correct functioning of the product, please inform your authorised
dealer.
6.1

Warnings

A warning is denoted by the letter A on the machine display, or Att in case of multiple machine
displays. The possible cause of the warning is signalled by the respective warning code (see
table).
The display of possible warning numbers depends on the machine version (interfaces/functions).
In case of multiple warnings, these are displayed in sequence.
Document machine warning and inform service personnel, if required.
Warning code
1
2
3
4
5
6
7
32
33
34
The warnings can be reset by pressing a push-button (see table):
Welding machine
control
Push-button
099-00T401-EW501
21.06.2018
Possible cause
Machine excess temperature
Half-wave failures
Welding torch cooling warning
Gas warning
See warning number 3
Welding consumable (wire electrode)
fault
CAN bus failure
Encoder malfunction, drive
Drive is operating under overload
conditions
JOB unknown
Smart
Remedy
Allow the machine to cool down
Check process parameters
Check coolant level and refill if necessary
Check gas supply
-
Check wire feeding (with machines with filler
wire)
Inform service
Inform service
Adjust mechanical load
Select alternative JOB
Classic
Comfort
Rectifying faults
Warnings
Smart 2
Synergic
Comfort 2
59

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T 4.01 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

T 4.09T 4.12

Table of Contents