LG VR6140LVM Owner's Manual page 26

Table of Contents

Advertisement

SMART-DIAGNOSIS MODE
Please refer to the table below to measure if voice message is heard after the smart diagnosis.
Voice message
Starting smart diagnosis mode. Please step away and
remove any items within 1 meter.
Unable to initiate smart diagnosis due to a low battery.
Smart Diagnosis mode will not operate with the mop plate
attached. Please try again after removing it.
HomBot will not charge due to infrared sensor error. Please try
smart diagnosis again after turning the main power switch on
the bottom of the HomBot 'Off' then 'On' again. If the problem
continues, please contact LG Electronics customer care.
HomBot will not charge due to ultrasonic sensor error. Please try
smart diagnosis again after turning the main power switch on
the bottom of the HomBot 'Off' then 'On' again. If the problem
continues, please contact LG Electronics customer care.
HomBot will not charge due to a problem with the cliff
sensors on bottom. Please wipe the sensors clean.
Please clean the camera sensor on bottom right side.
A problem has been found on the Gyro Sensor. Please try smart
diagnosis again after turning the main power switch on the
bottom of the HomBot 'Off' then 'On' again. If the problem
continues, please contact LG Electronics customer care.
Please check for foreign material on the left wheel.
Please check for foreign material on the right wheel.
A problem has been found on the left wheel sensor. Please try
smart diagnosis again after turning the main power switch on
the bottom of the HomBot 'Off' then 'On' again. If the problem
continues, please contact LG Electronics customer care.
A problem has been found on the right wheel sensor. Please try
smart diagnosis again after turning the main power switch on
the bottom of the HomBot 'Off' then 'On' again. If the problem
continues, please contact LG Electronics customer care.
A problem has been found with the brush. Please check for
any foreign material.
A problem has been found in the suction motor. Please try
smart diagnosis again after turning the main power switch on
the bottom of the HomBot 'Off' then 'On' again. If the problem
continues, please contact LG Electronics customer care.
A problem has been found in the acceleration sensor. Please try
smart diagnosis again after turning the main power switch on
the bottom of the HomBot 'Off' then 'On' again. If the problem
continues, please contact LG Electronics customer care.
Please, check the dust bin.
Smart diagnosis has failed to complete its diagnostics.
Please try again after turning the main power switch on the
bottom of the HomBot 'Off' then 'On' again.
24
Measures (Reference Page)
Please step away and clear out stuff around home
station within 1 m until smart diagnosis is complete. (23p)
Please restart the smart diagnosis function after battery
is charged. (16p)
Please start smart diagnosis again after removing the
mop plate.
If same message pops up even after the second smart
diagnosis, please contact LG Electronics service center.
If same message pops up even after the second smart
diagnosis, please contact LG Electronics service center.
Please clean 3 cliff detection sensors on the bottom of
HOM-BOT 2.0. (28p)
Please wipe the lower camera sensor on the right
bottom of the unit.(28p)
If same message pops up even after the second smart
diagnosis, please contact LG Electronics service center.
Please check dirt on the left wheel. (31p)
Please check dirt on the right wheel. (31p)
If same message pops up even after the second smart
diagnosis, please contact LG Electronics service center.
If same message pops up even after the second smart
diagnosis, please contact LG Electronics service center.
Please check if foreign material is on the rotation brush.
(33p)
If same message pops up even after the second smart
diagnosis, please contact LG Electronics service center.
If same message pops up even after the second smart
diagnosis, please contact LG Electronics service center.
Please open the cover to check dust bin.(32p)
Please try smart diagnosis again after turning on and
off the main power switch on the bottom of HOM-BOT
2.0 and do not touch or disturb HOM-BOT 2.0 until
the smart diagnosis is complete.

Advertisement

Table of Contents
loading

Table of Contents