System Configuration; Temperature Configuration; Thermostat-Remote Control Unit Configuration - Baxi MS THINK+ Installation Instructions Manual

For built-in twin-circuit installations
Table of Contents

Advertisement

Available languages

Available languages

5.1 SYSTEM CONFIGURATION

Enter menu 2 from the control panel, as described in section 5, and make the following settings:
PROGRAMME ROW
5710
(*)
5715
5721
5977
6020
(*)
6021
6024
(*)
6026
6200
The parameters marked with (*) must only be changed if version 1AT-2BT is installed.

5.2 TEMPERATURE CONFIGURATION

To set the flow temperature of the low temperature zone access the boiler functions from the Control Panel. Proceed as follows:
REMOTE CONTROL UNIT CONFIGURATION
• Access menu 2.
B
Operator unit
B
programme row 40 (Used as)
B (anti-clockwise)
B
programme row 42 (Allocated to room unit 1)
B
All heating circuits
LOW TEMPERATURE ZONE 1
• Access menu 2.
B
Temps / mode CH1
B
programme row 741 (Max. flow setpoint)
temperature 40°C) ---
LOW TEMPERATURE ZONE 2
• Access menu 2.
B
Temps / mode CH2
B
programme row 1041 (Max. flow setpoint)
temperature 40°C) ---
Reconfigure the Control panel according to its final use.

5.3 THERMOSTAT-REMOTE CONTROL UNIT CONFIGURATION

LOW TEMPERATURE ZONE 1 CONFIGURATION
AMBIENT THERMOSTAT
If a room thermostat is connected the parameter must be configured using the Remote Control unit. Access menu 2, as described
in section 5, and make the following settings:
PROGRAMME
VALUE TO SET
ROW
6046
Room thermostat CH1
7222520.03 (1-11/15)
VALUE TO SET
On
On
On
Room thermostat CH3
Temps / mode CH1
Temps / mode CH2
Limit thermostat CH
Limit thermostat CH
yes
B to confirm.
B.
Room unit 1
B to confirm.
B to confirm.
B to confirm.
B to confirm.
B to confirm.
B to confirm.
H2 input enabled as low temperature zone 1 room thermostat
DESCRIPTION
Heating circuit 1 enable
Heating circuit 2 enable
Heating circuit 3 enable
Enable thermostat for circuit 3 (contact 1-2 boiler terminal block M1)
Low temperature zone 1 enable
Low temperature zone 2 enable
EX21 input enabled as low temperature zone 1 protection
EX21 input enabled as low temperature zone 2 protection
Memorisation of all connected sensors
B.
B --- Set the required flow temperature (max. recommended
B --- Set the required flow temperature (max. recommended
DESCRIPTION
16