Heat Pump (R410A)
Model
Refrigerant
Refrigerant charge
Evaporator air fl ow
External static pressure
Condenser air fl ow
Control
Control wire length (Standard/Max) : Size
Compressor (Type/Quantity)
Air fi lter (Type/Quantity)
Air fi lter dimension (Length x Width x Thickness)
Heat Pump (R410A)
Model
Power supply
Max continuous current (Comp)
Full load current (FLA, Comp)
Locked rotor current (LRA, Comp)
The equipment fulfi ls the requirements in EN 61000-3-11 and is subject to conditional connection to the mains. It may be
connected in consultation with the supply authority. The equipment may only be connected to a mains supply with a system
impedance of less than the value stated in table below. The system impedance in the interface point may be obtained from
the supply authority.
Model
5RT90BR
5RT120BR
5RT150BR
5RT180BR
If the mains supply has a higher system impedance, short voltage dips may appear when the equipment is started or during
operation. This may infl uence or disturb the operation of other apparatuses, e.g. fl ickering lamps, especially those
connected to the same supply mains.
• All electrical work must be carried out by qualifi ed electrician and accordance with local supply requirement and
associate regulation.
Method for connecting electric wire
Before connecting the wire, consult the electric power company of jurisdiction.
(1) The entire wiring diagram of unit
(2) Wiring connection to unit
Route the power supply wires and control wire through the knockout holes in the unit.
Remove the service panels and connect the units power supply wires to terminal block inside the control box, as
shown.

PHYSICAL DATA

5RT90BR
kg
6.1
CFM
3300
L/S
1557
mmAq
Pa
CFM
8230
L/S
3884
2
m : mm
Scroll/1
mm
880 x 467 x 4

ELECTRICAL DATA

5RT90BR
V/Ph/Hz
A
26.0
A
21.0
A
111.0
Maximum impedance (Z

WIRE CONNECTION

a
b
PE
a. Power supply
c
g
b. Main switch/fuse
f
d
c. Power supply
e
1-13
5RT120BR
5RT150BR
R410A
5.8/5.8
7.2/7.2
4300
5650
2029
2667
15
147
6000/6000
6050/6050
2831/2831
2855/2855
Wired Rooftop Controller
15 / 100 : 3
Scroll/2
Scroll/2
Washable Saranet/2
1126 x 385 x 4 1126 x 435 x 4 1497 x 392 x 4
5RT120BR
5RT150BR
380-415/3N~/50
16.5/16.5
19.0/19.0
12.2/12.2
15.0/15.0
74.0/74.0
101.0/101.0
), ohm
max
0.22
0.23
0.21
0.21
d. Unit
e. Remote control
(fi eld supply)
f.
Connection wiring for
unit & remote controller
wiring for unit
g. Earth
5RT180BR
8.7/8.7
6600
3115
21
206
6450/6450
3044/3044
Scroll/2
5RT180BR
26.0/26.0
21.0/21.0
111.0/111.0