HealthyAir HA-SSC-G4 Owner's Manual

Source capture air purification system

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HA-SSC-G4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HealthyAir HA-SSC-G4

  • Page 1: Table Of Contents

    Source Capture Air Purification System HA-SSC-G4 Owner’s Manual Table of Contents HealthyAir® Series 1213 Filters Important Safety Instructions Technical Specifications Packaging Reference Packaging Notice Component Reference 7-11 Assembly Instructions 12-13 Operation Guidelines 14-16 Filter Replacement Maintenance 18-23 Basic Service and Troubleshooting...
  • Page 2: Healthyair Series 1213 Filters

    ® HealthyAir Model HA-SSC-G4 Source Capture Air Purification System with ® HealthyAir Series 1213 Filters ® HealthyAir ® ® HealthyAir HealthyAir eHEPA® Filter Pre-Filter Activated Carbon Filter HA-EH-1213 HA-PF-1213 HA-AC-1213...
  • Page 3: Important Safety Instructions

    WARNING Unplug the power cord before servicing or replacing filters. Failure to do so could result in serious personal injury and death. I. Important Safety Instructions Read the Owner's Manual and Important Safety Instructions carefully. Failure to follow these instructions could cause a malfunction of the filter or unsatisfactory performance.
  • Page 4: Technical Specifications

    II. Technical Specifications Model Number HA-SSC-G4-W/B Rated Voltage 120V/60HZ Power Consumption 200W Weight 48 lbs. (22 kg) Base Dimensions 16x14.4x38 in (400×360×950 mm) Flex Hose Length 5 ft. (1.52 m) Air Flow Rate 240 cfm (400 m Noise Level 56 dB...
  • Page 5: Packaging Reference

    III. Packaging Reference The Source Capture Air Purification System is shipped in three (3) cartons, as follows: Carton 1: (1) Air Purification Unit w/ (3) Filters, (4) Wheel Casters, (1) Remote Control, (1) Power Cord, (1) Screwdriver, (1) Manual Carton 2: (1) Inlet Tube, (1) Flex Hose, (1) Gooseneck, (1) Hose Clamp, (1) Centering Piece, (1) M16 Screw Carton 3: (1) Hood, (4) Thumb Screws, (1) LED Bulb, (1) Handle...
  • Page 6: Packaging Notice

    IV. Packaging Notice NOTICE Before operating the machine, do the following: 1. Open the Access Door 2. Remove the Activated Carbon Filter (HA-AC-1213) 3. Remove the plastic wrapping from the filter! 4. Re-install the Activated Carbon Filter 5. Replace and secure the Access Door Remove plastics wrapping from Activated Carbon Filter prior to use!
  • Page 7: Component Reference

    V. Component Reference 1. Outer Frame 13. HV PCB 25. Thumb Screws 2. Blower/Motor 14. Capacitor 26. Metal Piece 3. Base Plate 15. PCB 27. Hood 4. Caster Wheels 16. Inlet Tube 28. LED Bulb 5. Motor Mounting Plate 17. Hose Clamp 29.
  • Page 8: Assembly Instructions

    VI. Assembly Instructions 6.1 Install Wheel Casters 6.1.1 Place the unit on its side on a flat surface, as shown in Fig. 1. 6.1.2 Locate the four (4) Caster Wheels and the Screwdriver that are provided in Carton 1. 6.1.3 Unscrew and remove the screws that are pre-mounted onto the Base Plate on the bottom of the unit.
  • Page 9 VI. Assembly Instructions 6.2 Install Inlet Tube and Gooseneck 6.2.1 Unscrew and remove the six (6) M5x16 screws that are pre-mounted around the 4” Ø cutout on the top of the unit, as shown in Fig. 2. 6.2.2 Pull the LED Cable Plug out from within the 4” Ø cutout. With the Inlet Tube positioned slightly above the 4”...
  • Page 10 VI. Assembly Instructions 6.3 Install Hood and Flex Hose 6.3.1 Unscrew and remove the four (4) Thumb Screws from the Hood, as shown in Fig. 3-C. 6.3.2 Note that, there are two (2) holes on each side at the top of the Flex Hose.
  • Page 11 VI. Assembly Instructions 6.4 Install LED and Flex Hose 6.4.1 Slide the Flex Hose assembly over the Gooseneck until the bottom of the Flex Hose is positioned slightly above the top of the Inlet Tube, as shown in Fig. 4-D. 6.4.2 Connect the LED Cable by plugging together the male and female ends of the cable.
  • Page 12 VI. Assembly Instructions 6.5 Unwrap and Reinstall Activated Carbon Filter 6.5.1 Open and remove the Access Door, located on the Back Panel of the unit, by unscrewing the two (2) Thumb Screws. Note that, when opening the Access Door for the first time, some force may be required to pry open and break the seal between the Access Door and the unit.
  • Page 13: Operation Guidelines

    VII. Operation Guidelines 7.1 Source Capture System Positioning Place the HealthyAir® Source Capture Air Purification System in the desired location and adjust the Flex Hose to position the Hood approximately 6” from the source of the fumes. 7.2 Source Capture System Activation 7.2.1 Plug the Power Cord into the Power Socket, located on the bottom of...
  • Page 14 VII. Operation Guidelines 7.3 Source Capture System Controls • TIMER button is for operation of the timing clock. When this feature is in use the unit will automatically shut off after the set time expires. The system’s default timing is 4 hours of operation. To set the timer manually, press the TIMER button once for every hour you wish to run the machine (i.e.
  • Page 15: Filter Replacement

    VIII. Filter Replacement 8.1 Replacement Filters The HealthyAir® Source Capture System Model HA-SSC-G4 utilizes the HealthyAir® Series 1213 Replacement Filters, as follows: • HealthyAir® Pre-Filter Model No. HA-PF-1213 • HealthyAir® eHEPA® Filter Model No. HA-EH-1213 • HealthyAir® Activated Carbon Filter Model No.
  • Page 16 VIII. Filter Replacement 8.2 Filter Change 8.2.4 Install a new set of HealthyAir® Series 1213 Replacement Filters, consisting of the Pre-Filter (HA-PF-1213), eHEPA® Filter (HA-EH-1213) and Activated Carbon Filter (HA-AC-1213). 8.2.5 Reinstall the Access Door, ensuring that the Access Door is properly inserted back into its track.
  • Page 17 VIII. Filter Replacement 8.3 Filter Change Indicator Light Reset Once the filters have been replaced and the unit is powered on, the Filter Change indicator light may continue to flash. To reset the filter change timer and deactivate the flashing light, go through the following reset procedure: 8.3.1 Unplug the Power Cord from the Power Socket, wait a couple seconds and plug the Power Cord back into the Power Socket.
  • Page 18: Maintenance

    IX. Maintenance 9.1 Cleaning the Pre-Filter and eHEPA® Filter To extend the effective life of the Pre-Filter and eHEPA® Filter, remove the filters from the unit from time-to-time and clean them with a standard vacuum. 9.2 Cleaning Filter Compartment Visually inspect the interior of the Filter Compartment when the filters are removed from the unit during the filter replacement process.
  • Page 19: Basic Service And Troubleshooting

    X. Basic Service and Troubleshooting The Basic Service Guide should cover most performance issues. If you continue to experience issues after referring to this list, please contact Healthy Air Inc. 10.1 Air Purification System Inoperable If the unit fails to power on, the issue may be the result of one of the following causes.
  • Page 20 X. Basic Service and Troubleshooting 10.3 Air Purification System Power On but Fan Inoperable If the unit powers on but the fan fails to operate, the issue may be the result of a faulty motor and will require service by the manufacturer or a professionally licensed electrician.
  • Page 21 X. Basic Service and Troubleshooting 10.5 eGrid Activity Indicator Light Not Lit If the eGrid Activity indicator light fails to turn on when the eHEPA® system is on, the issue may be the result of one of the following causes and will require service by the manufacturer or a professionally licensed electrician.
  • Page 22 X. Basic Service and Troubleshooting 10.7 Flex Hose Fails to Remain in Position If the Flex Hose assembly fails to remain in position, the issue may be the result of one of the following causes and may require replacement parts. Possible Cause Solution Gooseneck out of place...
  • Page 23 X. Basic Service and Troubleshooting 10.9 LED Fails to Light If the LED fails to light up, the issue may be the result of one of the following causes and may require replacement parts. Possible Cause Solution LED Cable is not connected Reconnect LED Cable LED Mount is faulty Replace Hood...
  • Page 24: Basic Service And Troubleshooting

    X. Basic Service and Troubleshooting 10.11 Reduced Airflow and/or Odor Absorption If the fan/motor is properly functioning, but the unit exhibits reduced airflow and/or reduced odor absorption the issue may be the result of one of the following causes and may require replacement filters. Possible Cause Solution Pre-Filter is fully loaded...
  • Page 25: Electrical Wiring Schematic

    XI. Electrical Wiring Schematic Fig. (13) – Electrical Wiring Schematic...
  • Page 26: 1-Yeart Limited Warranty

    Healthy Air Inc. only makes this 1-Year Limited Warranty ("Limited Warranty") to the original retail purchaser who submits the enclosed Warranty Registration Card within 10 days of purchase by email to Sales@HealthyAir.com. This Limited Warranty applies only to the repair or replacement of any manufactured or supplied part of this product which, upon inspection by Healthy Air Inc.
  • Page 27: Product Registration Form

    Sales@HealthyAir.com. Note that, the Model Number and Serial Number are written on the sticker located at the bottom of the side panel of the unit. Please contact us at (800) 259-2535 or visit www.HealthyAir.com for Customer Service and Orders. Name:...

Table of Contents