HealthyAir HA-CMP-G2-R Owner's Manual

Ceiling mount air purification system

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HA-CMP-G2-R and is the answer not in the manual?

Questions and answers

Summary of Contents for HealthyAir HA-CMP-G2-R

  • Page 1: Table Of Contents

    Ceiling Mount Air Purification System HA-CMP-G2-R/HA-CMP-G2-OV Owner’s Manual Table of Contents HealthyAir® Series 1219 Filters Important Safety Instructions Technical Specifications Packaging Reference Component Reference 6-14 Installation Instructions Electrical Wiring Instructions Electrical Wiring Schematic 17-18 Operation Guidelines 19-23 Filter Replacement Maintenance...
  • Page 2: Healthyair Series 1219 Filters

    ® HealthyAir HA-CMP-G2-R & HA-CMP-G2-OV Ceiling Mount Air Purification Systems with ® HealthyAir Series 1219 Filters HA-PF-1219 HA-EH-1219 HA-CC-1219 www.HealthyAir.com...
  • Page 3: Important Safety Instructions

    WARNING Cut power to the unit before servicing or replacing filters. Failure to do so could result in serious personal injury and death. I. Important Safety Instructions Read the Owner's Manual and Important Safety Instructions carefully. Failure to follow these instructions could cause a malfunction of the filter or unsatisfactory performance.
  • Page 4: Technical Specifications

    II. Technical Specifications HA-CMP-G2-W-R Model Number HA-CMP-G2-W-OV Rated Voltage 120V/60HZ Power Consumption 200W Weight 65 lbs. (29.5 kg) Base Dimensions 24x24x15.4 in. (600×600×392 mm) Air Flow Rate 550 cfm (930 m Noise Level 56 dB...
  • Page 5: Packaging Reference

    III. Packaging Reference The Ceiling Mount Air Purification System is shipped in one (1) carton, that contains the following: • (1) Air Purification Unit • (3) Filters • (4) Eye Bolts • (1) Remote Control • (1) Manual Note: The Ceiling Mount Air Purification system is to be hard wired and does not have a power cord.
  • Page 6: Component Reference

    IV. Component Reference 1. Face Plate 11. Eye Bolt 2. Pre-Filter HA-PF-1219 12. Capacitor 3. eGrid 13. HV PCB ® 4. eHEPA Filter HA-EH-1219 14. PCB Board 5. Activated Carbon Filter HA-CC-1219 15. Wiring Box 6. Fan Coil 16. Safety Switch 7.
  • Page 7: Installation Instructions

    V. Installation Instructions 5.1 Installation of Eye Bolts 5.1.1 Carefully place the unit face down, as shown in Fig. 1. 5.1.2 Screw the four (4) Eye Bolts into the respective rivet nuts, located at the four corners of the Bottom Plate. 5.1.3 Ensure that each Eye Bolt is fully and securely installed.
  • Page 8 V. Installation Instructions 5.2 Optimal Unit Location ® The standard HealthyAir Ceiling Mount Air Purification System recirculates air back into the facility, after it is purified in a 3-stage filtration process. Note: Locate and install the unit such that it can be easily accessed and opened for periodic filter replacement.
  • Page 9 V. Installation Instructions 5.3 Mounting to I-Beam Ceiling Structure ® Using Fig. 3 as a guide, install the HealthyAir Ceiling Mount Air Purification System in accordance with all applicable building and mechanical codes. I-Beam Eye Bolt 12 Gauge Wire Rope...
  • Page 10 V. Installation Instructions 5.5 Outside Vent Application - Model HA-CMP-G2-OV ® The HealthyAir Ceiling Mount Air Purification Outside Vent System, model HA-CMP-G2-OV, is designed to enable filtered air to be discharged from the facility via exhaust ducting. The unit is equipped with two (2) 4”x10” Outside Vent Outlet Ports and (2) Outlet Port Cover Plates, that allow the exhaust duct to either be connected to the right or left side of the unit depending on which configuration is preferred.
  • Page 11 V. Installation Instructions 5.5 Outside Vent Application - Model HA-CMP-G2-OV ® 5.5.3 Install the HealthyAir Ceiling Mount Air Purification Outside Vent System in accordance with the instructions provided in Sections 5.1-5.4 herein. 5.5.4 Connect a universal 4’’x10” to 6” Ø Transition (not supplied) to the Outside Vent Outlet Port and ensure that the junction is secure.
  • Page 12 ® Conversely, the HealthyAir Ceiling Mount Air Purification Outside Vent System ® can be converted to a HealthyAir Ceiling Mount Air Purification Recirculating Vent System by removing the Outlet Vent Cover Plates from the back of the Face Plate. Recirculating Vent Face Plate Outside Vent Face Plate Fig.
  • Page 13 V. Installation Instructions 5.6 Converting Recirculating Vent to Outside Vent (Optional) Thumb Screws Recirculating Vent Face Plate Fig. (8) – Opening Face Plate 5.6.4 Locate and remove the eight (8) Hex Nuts that are preinstalled on the back of the Face Plate, as shown in Fig. 9. Outlet Vent Threaded Studs w/ Hex Nuts...
  • Page 14 V. Installation Instructions 5.6 Converting Recirculating Unit to Outside Vent (Optional) 5.6.5 Locate the two (2) Outlet Vent Cover Plates, shown in Fig. 10. Outlet Vent Cover Plate Hex Nut Fig. (10) –Outlet Vent Cover Plates 5.6.6 Install the Outlet Vent Cover Plates on the Face Plate Outlet Vents, as shown in Figs.
  • Page 15: Installation Instructions

    V. Installation Instructions 5.6 Converting Recirculating Unit to Outside Vent (Optional) 5.6.7 Reinstall the eight (8) Hex Nuts to secure the Outlet Vent Cover Plates on the Face Plate. 5.6.8 Close the Face Plate and reinstall the two (2) Thumb Screws, as shown in Fig.
  • Page 16: Electrical Wiring Instructions

    VI. Electrical Wiring Instructions ® Note: The HealthyAir Ceiling Mount Air Purification system must be hard wired when recess mounted. All wiring must comply with applicable electrical codes and ordinances. 6.1 Instructions to Hard Wire 120V AC, 60 Hz 6.1.1 Install an external circuit breaker sized for a Maximum 2.5 AMP to bring power to the unit.
  • Page 17: Electrical Wiring Schematic

    VII. Electrical Wiring Schematic Fig. (14) – Electrical Wiring Schematic...
  • Page 18: Operation Guidelines

    VIII. Operation Guidelines 8.1 Power Supply and Activation The input power to the unit should include an external circuit breaker with a 2.5 AMP Maximum Current Rating. 8.1.1 Provide power to the unit by turning the circuit breaker to the ON position.
  • Page 19: Operation Guidelines

    • LIGHT button, on the Control Panel and Remote Control, is inactive. ® Note that, LED lighting is an optional feature only on HealthyAir ® Ceiling Mount Source Capture Air Purification Systems.
  • Page 20: Filter Replacement

    ® HealthyAir Activated Carbon Filter Model No. HA-CC-1219 ® Note that, only manufacturer supplied HealthyAir Replacement Filters are ® compatible with HealthyAir Ceiling Mount Air Purification Systems. No other replacement filters are to be used with this unit. The improper use of non-manufacturer supplied filters will void any potential warranty claim.
  • Page 21 IX. Filter Replacement 9.2 Filter Change Hinge Thumb Screw Face Plate Fig. (16) – Opening Face Plate to Access Filters 9.2.3 Unscrew and remove the four (4) Thumb Screws, which secure the Filter Housing, as shown in Fig. 17. 9.2.4 Gently pull the Filter Housing straight down, to access the filters. The Filter Housing slides down a track comprised of four rods.
  • Page 22 Housing Thumb Screw Fig. (17) –Lowering Filter Housing to Access Filters ® 9.2.6 Install a new set of HealthyAir Series 1219 Replacement Filters into the Filter Housing, as follows and as shown in Fig. 18: • ® Insert the HealthyAir Pre-Filter: HA-PF-1219 •...
  • Page 23 IX. Filter Replacement 9.2 Filter Change 9.2.7 Push the Filter Housing up to reinsert it within the unit. While holding the Filter Housing in place, screw in the four (4) Thumb Screws to secure it the housing to the body of the unit. 9.2.8 Swing the Face Plate back up, so that it is flush and properly aligned with the body of the unit and secure the Face Plate by screwing in the (2) Thumb Screws.
  • Page 24: Filter Replacement

    IX. Filter Replacement 9.3 Filter Change Indicator Light Reset Once the filters have been replaced and the unit is turned on, the Filter Change indicator light may continue to flash. To reset the filter change timer and deactivate the flashing light, go through the following reset procedure: 9.3.1 Turn the unit Power On.
  • Page 25: Maintenance

    X. Maintenance Caution: The HV Contact Spring may store a slight charge even after the unit is powered off. Avoid direct contact with the HV Contact Spring after the filters have been removed from the Filter Housing. ® 10.1 Cleaning the Pre-Filter and eHEPA Filter ®...
  • Page 26: Basic Service And Troubleshooting

    XI. Basic Service and Troubleshooting The Basic Service Guide should cover most performance issues. If you continue to experience issues after referring to this list, please contact Healthy Air Inc. 11.1 Air Purification System is Inoperable If the unit fails to power on, the issue may be the result of one of the following causes.
  • Page 27 XI. Basic Service and Troubleshooting 11.3 Air Purification System Power is On but Fan Inoperable If the unit powers on but the fan fails to operate, the issue may be the result of a faulty motor or board and will require service by the manufacturer or a professionally licensed electrician.
  • Page 28 XI. Basic Service and Troubleshooting 11.5 Filter Change Indicator Light Flashing If the unit is properly functioning and the Filter Change indicator light is flashing, the default filter change timer has expired, and the filter should be replaced. Possible Cause Solution Filter change cycle timer expired Replace filter and reset timer...
  • Page 29: Basic Service And Troubleshooting

    XI. Basic Service and Troubleshooting 11.7 Remote Control is Inoperable If the Remote Control fails to operate the unit, the issue may be the result of one of the following causes and may require replacement parts or service by the manufacturer or a professionally licensed electrician. Possible Cause Solution Battery nearly exhausted...
  • Page 30: 1-Yeart Limited Warranty

    Healthy Air Inc. only makes this 1-Year Limited Warranty ("Limited Warranty") to the original retail purchaser who submits the enclosed Warranty Registration Card within 10 days of purchase by email to Sales@HealthyAir.com. This Limited Warranty applies only to the repair or replacement of any manufactured or supplied part of this product which, upon inspection by Healthy Air Inc.
  • Page 31: Product Registration Form

    Sales@HealthyAir.com. Note that, the Model Number and Serial Number are written on the sticker located at the bottom of the side panel of the unit. Please contact us at (800) 259-2535 or visit www.HealthyAir.com for Customer Service and Orders. Name:...

This manual is also suitable for:

Ha-cmp-g2-ov

Table of Contents