68
Electrical Systems
Special Tools
1. Digital volt, ohm meter.
OTC PN. OEM1428 or equivalent
2. Electrical "skin over grease"
OTC PN. TOR50547
TORO GM 345 / 325-D
Helpful Hints
1. Interlock switches
Neutral switch closed with traction pedal in
neutral
PTO switch closed with PTO disengaged
Seat switch open with no operator in the seat
2. Unit will start without an operator in the seat, if
the PTO is disengaged and the traction pedal is
in neutral.
3. Unit will run without an operator in the seat, if
the PTO is disengaged and the traction pedal is
in neutral
4. Unit will shut off if operator leaves the seat and
the traction pedal is depressed or PTO is
engaged
5. Interlock switches should be checked daily
6. Interlock switches should be replaced every 2
years or 1500 hrs.