AUTOMATIC IGNITER. If your automatic ignition system should
ever need troubleshooting, repair or replacement, please contact your
Authorized Dealer. Your appliance can be lit manually without using the
automatic i
iter by following the procedure shown below.
If your stove is set up to run on a thermostat, the thermostat circuit
needs to be closed (as if permanently in the demand mode). The thermo­
stat wires should be removed from the rear of the stove and replaced
with the red jumper wire originally supplied with your stove. If a jumper
wire is not available the thermostat should be set to the highest setting.
This will keep the stove in the demand mode.
Press the ON switch on the control panel.
1.
2.
Wait approximately 2 1/2 minutes while the pellets prime the grate
(the pellets will stop feeding automatically).
3.
Place a small amount ofan approved (non-volatile) fire starter on
top of the pellets in the grate, (see your dealer for appropriate fire
starting products). DO NOT USE FLAMMABLE LIQUIDS TO
START YOUR STOVE!
4.
Light the "fire starter" with a match and close the door.
The photoelectric eye will detect that a flame is present and will
5.
begin feeding pellets in approximately 2 minutes.
6.
The control panel will continue to go through the normal start-up
cycle and the flame should be well established within 10 minutes
from the time the ON button was initially pressed. Remember -you
are now in manual mode and heat settings should be selected to the
desired room heat level.
Press the stove ON/OFF switch on the control panel to shut down your
stove. The control will initiate the shutdown procedure and safely shut
down your stove.
AIR WASH -To inhibit buildup of soot on the door glass, air is delivered to the
glass through an air wash system located in the doorfiame surrounding the glass.
AUGER- The auger transfers the fuel down the burner tube into the firepot.
POWER
I DISCONNECT
THERMOSTAT
CONNECTOR
JUMPER
6AMP
FUSE
JUMPER 1-3
JUMPER24
gn
MANUAL LIGHTING
TURNING OFF YOUR STOVE
COMPONENT DEFINITIONS
I•
4
3
(INLET) HIGH LIMIT SWITCH
l. 2 50-30F (N/C)
brown
white)
HIGH LIMIT SWITCH
L250-30F (N/C)
(black)
(purple)
(purple)
(red)
(red)
NOTE: SWITCH CONDITIONS GIVEN AT
ROOM TEMPERATURE. STOVE OFF
N/C = NORMALLY CLOSED
Reference Information
WIRING DIAGRAM (120V AC)
Page 5
AUGER MOTOR - The auger motor specifications are: .4 amp, I 1pm (revolu­
tions per minute). The auger motor drives the auger to deliver fuel to firepot
BLOWER, ROOM AIR-The blower specifications are: 150 CFM (cubic feet
per minute), .8 amp, 2178 rpm (revolutions per minute). The blowers function is
to transfer the heat from the appliance to heat the room air.
BLOWER, COMBUSTION - The blower specifications are: 95 CFM (cubic
feet per minute), 1.0 amp, 2880 1pm (revolutions per minute). This fan operates
at 2800 RPM. It has a radial impeller to deliver more air to the firepot. It pulls
air into the firepot by creating a negative pressure. This is done by extracting the
exhaust gases out of the firebox and pushing the exhaust downstream to the flue
exit
DISC, CONVECTION HIGH LIMIT (1250-30F, N/C) -lfthe temperature of
the convection air chamber reaches 250
and stop the flow of electricity to the auger motor. It will not automatically reset
until it has cooled below 220
F).
DISC, INLET HIGH LIMIT (L250-30F, N/C) - If the exhaust flow is unable
to leave at the required rate then heated exhaust will back up resulting in heat
activation of this switch (trips at 250
auger motor. It will not automatically reset until it has cooled below 220
DOOR SWITCH (Profile 30) - If the door is opened during operation (on
model Profile 30), this switch disconnects power to the auger motor resulting in
the unit shutting down.
FIREPOT -The firepot is where combustion occurs.
HOPPER -The hopper is where the pellets are stored.
HEAT OUTPUT SWITCH -This is the main power switch, which controls
power to the feed s
tem auger motor and draft fan. It has 3 feed rate settings,
which controls the burn rate.
PHOTOEYE - The photoeye is designed to signal the control board to discon­
tinue power to the auger motor) if it does not sense a flame in the firepot.
PRESSURE SWITCH -The pressure switch is a safety device used to shut off
the feed system (auger motor) if there is too much back pressure in venting
system Some possible causes are as follows:
♦ The venting s
tem is obstructed.
♦ High Altitude or other misc. environmental conditions affecting exhaust flow.
♦ Improper Venting S
tem
DOOR SWITCH - N/C
(PROFILE 30)
(bl a ck)
bl u e
brown
black
IGNITER
°
ys
ys
ys
F ., the high limit auto reset will "trip"
F will stop the flow of electricity to the
F).
°
°
°
,