Mobile Home Installation
IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTIONS, THE FOLLOWING INSTRUCTIONS MAY BE
• Stove must be permanently bolted to the floor.
• Stove must have a permanent outside air source.
• Stove must be permanently electrically grounded to the steel chassis of the home. The location selected
for ground attachment to the stove must be dedicated for this purpose.
• Refer to page 17 for list of commonly used vent components.
e
NOTE: THE GROUNDING OF THIS PRODUCT, AT INSTALLATION, MUST COMPLY WITH NFPA-70
STANDARDS, CSA C22.1 IN CANADA, AS WELL AS ANY LOCAL CODES.
WARNING:
CAUTION:
Floor
Chassis
MOBILE HOME EXHAUST VENT PIPE INSTALLAT ION GUIDELINES
Use only listed type "L" pellet vent pipe. Pipe should extend at least 3 feet above the part of the roof
through which it passes. The top of the pipe should be at least 2 feet above the highest required ele­
vation of any part of the mobile home within 10 feet of the pipe.
If exhaust vent exits the mobile home at a location other than the roof, and exits at a point 7 feet or
less above the ground level on which the mobile home is position a guard or method of enclosing
the pipe shall be provided at the point of exit for a height of up to 7 feet. The openings, if any, in this
guard shall not allow a 3/4" rod to pass through. A 1/2" rod could pass through but should not be
able to touch the pipe when inserted through the opening a distance of 4 inches.
REQUIRED BY LOCAL, STATE OR FEDERAL BUILDING CODES:
DO NOT INSTALL IN A SPACE USED AS A BEDROOM.
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL
AND CEILING/ROOF MUST BE MAINTAINED.
Page 14
Model Traditions P11 - Freestanding
Floor Pad
Non-combustible