Lennox SEREFINA CI1500DVF series Installation Instructions Manual

Direct vent

Advertisement

Quick Links

FREESTANDING
VENTED GAS
FIRED ROOM
HEATERS
These appliances may be installed in
an aftermarket permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
A French manual is available upon
request. Order P/N 775,147CF
Ce manuel d'installation est dis-
ponible en francais, simplement en
faire la demande. Numéro de la pièce
775,147CF.
Report No. 116-S-08-5
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammable vapors or liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by a
qualifi ed installer, service agency or the gas sup-
plier
.
INSTALLATION INSTRUCTIONS
Model CI1500DVF Series
Serefi na Series Direct Vent Gas Stoves
P/N 775,147M Rev D, 11/2006
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides infl ammables dans
le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifi é
installeur, agence de service ou le fournisseur de gaz.
MANUAL
Model CI2500DVF Series

Advertisement

Table of Contents
loading

Summary of Contents for Lennox SEREFINA CI1500DVF series

  • Page 1 INSTALLATION INSTRUCTIONS MANUAL FREESTANDING VENTED GAS FIRED ROOM HEATERS These appliances may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes. A French manual is available upon request. Order P/N 775,147CF Ce manuel d’installation est dis- ponible en francais, simplement en faire la demande.
  • Page 2: Table Of Contents

    fi red heater. It cal Code ANSI/ NFPA 70 - latest edition. In is our goal at Lennox Hearth Products to provide you, our valued customer, with an appli- Canada, the current CSA C22-1 Canadian ance that will ensure you years of trouble free warmth and pleasure.
  • Page 3: High Altitude

    Ne pas se servir de cet appareil s'il a été Tables 2 and 3 show the units' gas pressure WARNING plongé dans l'eau, complètement ou en requirements: partie. Appeler un technicien qualifi é pour Do not place clothing or other inspecter l'appareil et remplacer toute partie Inlet Gas Supply Pressure du système de contrôle et toute commande...
  • Page 4: Specifi Cations

    Effi ciency * 87% (LP) 85% (LP) *Based on maximum vent confi guration. Note: Due to Lennox’ ongoing commitment to quality , all specifi cations, ratings and dimen- sions are subject to change without notice. Figure 1 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 5: Appliance And Vent Clearances

    CLEARANCES TO COMBUSTIBLE MATERIALS / FLOOR PROTECTION Clearance To Combustibles and Alcove Dimensions • The location should also be free of electrical, plumbing or other heating/air conditioning ducting. Side View / Rear Wall or Alcove Clearances • Due to high temperatures, this appliance should be located out of traffi c and away from furniture, draperies and not in windy or drafty areas.
  • Page 6: Manufactured Home Requirements

    7. Are below grade penetrations of the gas line These instructions should be used as a MANUFACTURED (MOBILE) HOME allowed? guideline and do not supersede local codes in REQUIREMENTS 8. Is concealed gas piping allowed? any way. Install vent according to local codes, 9.
  • Page 7 EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9” in U.S. = 12” in Canada Detail D 3 ft.
  • Page 8: Typical Installation Sequence

    TYPICAL INSTALLATION SEQUENCE The proper gas line diameter must be used B. Remove stove body from pallet (READ to run from the supply regulator (at the gas CAUTION BELOW). company meter) to the appliance. Never use See the Page numbers references in the galvanized or plastic pipe.
  • Page 9: Step 5 Remove Firebox Contents

    A. Optional accessories include a wall ther- B. Reach under the bottom front of the front Blower Wiring Diagram mostat, blower kit, brick liner kit, warming glass enclosure and pull it forward as shown shelves and a standard or deluxe remote in Figure 7.
  • Page 10: Step 8 Install Lower Access Door

    CAUTION: Under no circumstances should Step 8: INSTALL LOWER ACCESS DOOR . General Information: These instructions these appliances be vented to other rooms should be used as a guideline and do not or buildings. These appliances must only be supersede local codes in any way. Install vent Install the lower access door by inserting the vented to the outside.
  • Page 11 Vertical Termination Horizontal Termination The vent must rise vertically, a minimum of 24" (610 mm) off the A vertical vent system must terminate no less than 8 feet ( 2.44 meters) top of the appliance for Natural Gas and 36" for Propane Gas before and no more than 40 feet / 12 meters ( above the appliance fl...
  • Page 12 Direct Vent Retrofi t Of Existing Chimney System Installing Support Brackets An existing Class-A (wood-burning) Metal Chimney or Masonry Install support brackets per vent manufacturers instructions. Chimney can be converted to a direct vent system. Use one of the following chimney conversion kits listed below. Have the existing Vertical Vent Installation chimney system inspected by a professional prior to the conversion.
  • Page 13 DIRECT VENT SYSTEM COMPONENTS The following "Security Secure Vent " or "Simpson Dura-Vent" brand Direct-Vent components may be safely used with these appliances. IMPORTANT NOTE: Seal the fi rst section of pipe to the stove collar using mill-pac black, high temperature sealant. Model # SIMPSON DURA-VENT Description Model #...
  • Page 14: Step 10 Connect Gas Line

    Step 10. CONNECTING GAS LINE Carefully install the ember strip and seven- piece log set into the fi rebox as shown in these instructions. All logs should fi t onto Gas Flex Line Connector corresponding pins and/or log stoppers. This will ensure a proper fl ame and safe Valve 3/8"...
  • Page 15: Step 12 Reinstall Front Glass

    4. Place the center log piece over the cor- 7. Install the center top twig onto the cor- responding pin on the rear log and align it responding pins next to the front left log as with the indentation on front left log as shown shown in Figure 23.
  • Page 16: Step 13 Perform Leak Test

    The fl ame should project 1" (25 mm) beyond Fasten the two latches located beneath the SIT Millivolt Gas Valve Controls fi rebox fl oor to the glass frame vee-fl ange. the hood at all three ports (Figure 32). HI / LO Knob Inlet Close both the latches securely.
  • Page 17: Step 16 Install Top, Trivet & Ash Lip

    Sooting is indicated by black puffs developing The adjustment rod and associated adjustable Step 16. INSTALL STOVE TOP, TRIVET at the tips of very long orange fl ames. Sooting air shutter is patented technology. Flame adjust- AND ASH LIP results in black deposits forming on the logs, ments can be made quickly and accurately to A.
  • Page 18: Rating Plates

    MODEL NO. MODEL NO. CI2500DVF CI1500DVF SERIES SERIES MANUFACTURED AT: SANTA TERESA, NM MANUFACTURED AT: SANTA TERESA, NM FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE 0-4500 FT (0-1370 M) ALTITUDE 0-4500 FT (0-1370 M) MIN.
  • Page 19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 20 Lennox reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information. Printed in U.S.A. © 2003 Lennox Hearth Products P/N 775,147M REV.

This manual is also suitable for:

Serefina ci2500dvf series

Table of Contents