Portion control scale, 22 pounds/352 ounces/10 kilograms by grams, ounces, troy ounces, pounds, hong kong tael, taiwan tael, grains, pennyweights, mommes, tolas, carats and free factor units
Structural alterations may not be made to the scale. This can lead to incorrect weighing results, faults concerning safety regulations as well as to destruction of the scale. The scale may only be used in compliance with the described guidelines. Varying areas of application/planned use must be approved by CDN in writing.
Before using the external mains adapter, make sure that the printed voltage must comply with the local voltage. • Only use original CDN mains adapter. The use of other adapter is subject to approval by CDN. Connecting Peripheral Devices Before connecting or disconnecting of additional devices (printer, PC) to the data interface, always...
Page 4
Calibration As the gravity value is not the same at every location on earth. To achieve best accuracy, the scale is highly recommended to be calibrated in compliance with the gravity at the place of use. This calibration process must be carried out for the first time of use, after each change of location as well as in case of environment temperature change.
Page 5
Battery Status If the batteries are exhausted, "LO" appears in the display. Press ON/OFF key and replace the batteries immediately. If the scale is not used for a longer time, take out the battery and store it separately. Leaking battery liquid could damage the scale.
Page 6
The taring process can be repeated any number of times, e.g. when adding several components for a mixture (adding). The limit is reached when the total weight reaching full capacity of the scale. After removing the tare vessel, the total weight is displayed as negative reading. After finishing the weighing process, press the SET/TARE key again, the scale display goes back to zero.
6. Net-Total Weighing It is useful for control purposes if a mixture of several components is weighed in a tared vessel and the final sum weight of all weighed components is displayed (net-total is the total weight excluding the tare vessel).
8. Weighing Units (Unit) Turn on scale using the ON/OFF key and wait for the zero display. Press and hold the FUNCTION key until "UNIT" appears on the display. Press SET/TARE key, the selected unit is displayed. Use the UNIT/COUNT key or HOLD/PRINT key to select between different units (see following table). Press the SET key to select the default weighing unit.
Display Adjustment Function Good contrast display which bL on Back light ON can also be read in darkness bL oFF Back light OFF Battery saving Back light will be switched off bL Ch automatically if no weight Battery saving change for 10 seconds. SET/TARE Press the key to confirm setting.
14. RS232C Interface Data from the scale can be output via the RS232C interface to other devices, e.g. printer, PC ... Technical Data 8-bit ASCII Code 1 start bit, 8 data bits, 1 stop bit, no parity bit Baud rate selectable at 1200, 2400, 4800 , 9600 and 19200 baud 9-pin D-sub female connector Use correct interface cable (max.
Page 11
Explanation of the output data Pr PC: Press the HOLD/PRINT key to send the stable weight according to below formats. a. Format for stable weight 13 14 S N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 B U1 U2 U3 CR LF b.
Page 12
Symbols using for the data format Blank or M Blank or minus sign (-) 10 numeric ASCII codes for weight values including 1 … decimal places or blanks 3 ASCII codes for weighing unit pcs. / % / or blank 1 …...
CDN, PO Box 10947, Portland, OR 97296-0947. This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions, inadequate maintenance, normal wear and tear, tampering, accident, misuse, unauthorized modification, obvious carelessness or abuse.