W
iring diagram
Fasten the lead wire
(clear) of noise
suppressor with screw.
Insert the tube for protecting
lead wires, deep in the motor housing.
Lead holder
Hold the following lead wires
with this lead holder.
* Lead wire (see through) of noise
suppressor
This lead wire has to be put in
the bottom of lead holder.
* Field lead wire (purple) to be
connected to switch
* Field lead wire (white) to be
connected to switch
* Field lead wire (black) to be
connected to insulated terminal
Put lead wires of power supply cord
on the left side of rib.
Line coil
Terminal block
Do not cross the lead wires with which
line coil and terminal block are connected.
Right side
Line
coil
Terminal block
Left side
Lead holder
Hold the following lead wires
with lead holder.
* Field lead wire (red) to be
connected to switch
* Field lead wire (orange) to be
connected to switch
* Field lead wire (black) to be
connected to insulated terminal
Resister
The lead wires (red or white ) for
connecting line coil with terminal
block have to be put as shown.
(between resister and noise
suppressor.
Noise suppressor
Rib
Put the insulated terminals
under the lead wires of
power supply cord.
P 8 / 8