Replacing gas valve
Hide thumbs Also See for 715ES:

Advertisement

18 | G3-28 | 715ES, C800ES, C920ES, C920ESC, 2400ES, 2700ES
Installing gas valve
1. Replace both the grey fiber washer on the left side of the gas
valve and the rubber gasket on the top of the gas valve.
2. Hold replacement gas valve in place and reinstall the three allen
screws into the top of the gas valve. (Fig. 3, pos. 4).
3. Reinstall 30mm hex nut on the left side of gas valve.
(Fig. 3, pos. 3)
4. Open manual gas shutoff valve and check for leaks at all connec-
tions.
5. Reinstall silicone pressure balance tube to right side of gas
valve. (Fig. 3, pos. 2).
6. Reconnect wire connection to gas valve. (Fig. 3, pos. 1).
Calibrating gas valve
1. Reinstall combustion cover. (Fig. 1, step 2).
2. Return control unit to normal position and secure with 3 Phillips
head screws. (Fig. 2)
3. Plug in water heater and push power button to the "ON" posi-
tion.
4. Open a hot water tap. If heater fires, adjust CO₂ using service
bulletin G3-12 Measuring and adjusting CO₂.
5. If the heater does not fire, allow the unit to display the EA error
code and shut off hot water tap. The fan will continue to run to
purge the heater of gasses. Continue to the next section for a
rough gas valve adjustment.
Rough gas valve adjustment
Note: Do not forcefully tighten adjustment screws past bottom out
point. Stop bottoming out screw when resistance is felt. Failure
Data subject to change without notice | Printed in the USA | BTC 710002312 A | 01.2009
Figure 3
to do so will damage the gas valve.
1. Locate adjustment screw on gas valve. Loosen Phillips head
screw so retaining cover can be rotated to expose brass slotted
screw. (Fig. 4, pos. 1 & 2).
2. Turn brass slotted screw clockwise gently until it bottoms out
and/or screw resistance increases. (Fig. 4, pos. 3).
3. Once the slotted screw is bottomed out, make the following
adjustment to the slotted screw depending on your model and
gas type. (Fig. 4, pos. 3)
For models GWH 715 ES/GWH 2700 ES/ GWH 2400 ES:
Natural Gas: 2.5 turns counter-clockwise on brass slotted screw
Liquid Propane: .75 turns counter-clockwise on brass slotted screw
For model GWH C 800 ES:
Natural Gas: 3 turns counter-clockwise on brass slotted screw
Liquid Propane: 1 turn counter-clockwise on brass slotted screw
For models GWH C920 ES/GWH C 920 ESC:
Natural Gas: 2.5 turns counter-clockwise on brass slotted screw
Liquid Propane: Leave brass slotted screw bottomed out
4. Open a hot water tap. If heater fires, adjust CO₂ using service
bulletin G3-12 Measuring and adjusting CO₂. If heater still does
not fire, contact Bosch Thermotechnology Corp.
5. Reinstall brass slotted screw cover and secure with Phillips
screw. (Fig. 4, pos. 1 & 2).
!
FAILURE TO PROPERLY CALIBRATE THE
HEATER'S CO₂ LEVEL MAY RESULT IN A
HAZARDOUS CONDITION CAUSING
SEVERE PERSONAL INJURY OR DEATH.
1
1
2
2
WARNING
Bosch Thermotechnology Corp.
50 Wentworth Avenue
Londonderry, NH 03053
Tel: 1-866-642-3198
Fax: 1-603-584-1681
www.boschhotwater.com
Bosch Thermotechnology Corp.
Service bulletin
Figure 4
3
3

Advertisement

loading

This manual is also suitable for:

C800es2400es2700esGwh c 920 esGwh c920esc