Communicaion Port
The following two ports are assigned for the command control.
TCP #23
TCP #9715
Configure the following items form a web browser when command control is used.
Port Settings
Port open
Network Control
Port1 (Port: 23)
Authentication
Port open
Network Control
Port2 (Port: 9715)
Authentication
When the authentication setting is enabled, the following settings are required.
Security Settings
Authentication
Password
Network Control
Re-enter
Authentication
Password
LX501/LX601i User Manual-Technical Guide
Command Control via the Network
Click the [Enable] check box to open [Network
Control Port1 (Port: 23)] to use TCP #23.
Default setting is "Enable".
Click the [Enable] check box for the
[Authentication] setting when authentication
is required.
Default setting is "Disable".
Click the [Enable] check box to open [Network
Control Port2 (Port: 9715)] to use TCP
#9715.
Default setting is "Enable".
Click the [Enable] check box for the
[Authentication] setting when authentication
is required.
Default setting is "Enable".
Enter the desired authentication password.
ConfirmThis setting will be the same for
[Network Control Port1 (Port: 23)] and
[Network Control Port2 (Port: 9715)].
Default setting is blank.