PeakTech 5995 Operation Manual

PeakTech 5995 Operation Manual

Digital ac/dc-power supply
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

1. Safety Precautions
This product complies with the requirements of the following European Community
Directives: 2004/108/EG (Electromagnetic Compatibility) and 2006/95/EG (Low
Voltage) as amended by 2004/22/EG (CE-Marking).
To ensure safe operation of the equipment and eliminate the danger of serious
injury due to short-circuits (arcing), the following safety precautions must be
observed.
Damages resulting from failure to observe these safety precautions are exempt
from any legal claims whatever.
*
Prior to connection of the equipment to the mains outlet, check that the
available mains voltage corresponds to the voltage setting of the equipment.
*
Do not place the equipment on damp or wet surfaces.
*
Do not exceed the maximum permissible input ratings (danger of serious
injury and/or destruction of the equipment).
*
Replace a defective fuse only with a fuse of the original rating. Never short-
circuit fuse or fuse holding.
*
Check test leads and probes for faulty insulation or bare wires before
connection to the equipment.
*
Please use only 4mm-safety test leads to ensure immaculate function.
*
To avoid electric shock, do not operate this product in wet or damp
conditions. Conduct measuring works only in dry clothing and rubber shoes,
i. e. on isolating mats.
*
Comply with the warning labels and other info on the equipment.
*
The measurement instrument is not to be to operated unattended.
*
Do not subject the equipment to direct sunlight or extreme temperatures,
humidity or dampness.
*
Do not subject the equipment to shocks or strong vibrations.
*
Do not operate the equipment near strong magnetic fields (motors,
transformers etc.).
*
Keep hot soldering irons or guns away from the equipment.
*
Allow the equipment to stabilize at room temperature before taking up
measurement (important for exact measurements).
*
Use caution when working with voltages above 35V DC or 25V AC. These
Voltages pose shock hazard.
*
Periodically wipe the cabinet with a damp cloth and mid detergent. Do not
use abrasives or solvents.
*
The meter is suitable for indoor use only
*
Do not operate the meter before the cabinet has been closed and screwed
safely as terminal can carry voltage.
-7-
*
Do not store the meter in a place of explosive, inflammable substances.
*
Do not modify the equipment in any way
*
Do not place the equipment face-down on any table or work bench to
prevent damaging the controls at the front.
*
Opening the equipment and service – and repair work must only be
performed by qualified service personnel
*
Measuring instruments don't belong to children hands.
Cleaning the cabinet
Prior to cleaning the cabinet, withdraw the mains plug from the power outlet.
Clean only with a damp, soft cloth and a commercially available mild household
cleanser. Ensure that no water gets inside the equipment to prevent possible
shorts and damage to the equipment.
-8-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5995 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PeakTech 5995

  • Page 1 1. Safety Precautions Do not store the meter in a place of explosive, inflammable substances. Do not modify the equipment in any way This product complies with the requirements of the following European Community Do not place the equipment face-down on any table or work bench to Directives: 2004/108/EG (Electromagnetic Compatibility) and 2006/95/EG (Low prevent damaging the controls at the front.
  • Page 2: Specifications

    Eine Fuse 4A / 250V F ; 5x20mm Wiederholung der Kalibrierung nach Ablauf von einem Jahr wird empfohlen. Dimensions 380 x 140 x 300mm (BxHxW) Weight 12 kg ® © PeakTech 06/2009/th Accessories Power cable and instruction manual...
  • Page 3: Inbetriebnahme Des Gerätes

    4. Inbetriebnahme des Gerätes 3. Front Panel Controls Vor Anschluss/Inbetriebnahme des Gerätes, unbedingt darauf achten, dass die 17 18 15 16 Spannung und die Polarität richtig angeschlossen sind. Verpolung kann zur Beschädigung des Netzgerätes führen. Eine defekte Sicherung darf nur durch eine Sicherung mit gleichen Maßen und Werten ersetzt werden.
  • Page 4 4. Precautions for using the power supply 3. Bedienelemente 15 16 17 18 Caution ! Before connecting the mains plugs of the power supply to the main outlet and switching on the equipment, be sure that the correct main voltage is available and polarity has been correctly observed.
  • Page 5: Technische Daten

    We recommend to calibrate the unit again, after one year. Sicherung 4A / 250V F ; 5x20mm Abmessungen 380 x 140 x 300mm ® (BxHxT) © PeakTech 06/2009/Th Gewicht 12 kg Zubehör Netzkabel und Bedienungsanleitung Heinz-Günter Lau GmbH - Kornkamp 32 - DE-22926 Ahrensburg / Germany...
  • Page 6 Gerät keinen extremen Temperaturen, direkter Sonneneinstrahlung, extremer Luftfeuchtigkeit oder Nässe aussetzen. Starke Erschütterung vermeiden. Heiße Lötpistolen aus der unmittelbaren Nähe des Gerätes fernhalten. Aufnahme Messbetriebes sollte Gerät Umgebungstemperatur stabilisiert sein (wichtig beim Transport von kalten in warme Räume und umgekehrt) Messungen von Spannungen über 35V DC oder 25V AC nur in Übereinstimmung mit den relevanten Sicherheitsbestimmungen vornehmen.
  • Page 7: Sicherheitshinweise Zum Betrieb Des Gerätes

    1. Sicherheitshinweise zum Betrieb des Gerätes Dieses Gerät erfüllt die EU-Bestimmungen 2004/108/EG (elektromagnetische Kompatibilität) und 2006/95/EG (Niederspannung) entsprechend der Festlegung im Nachtrag 2004/22/EG (CE-Zeichen). Zur Betriebssicherheit des Gerätes und zur Vermeidung von schweren Verletzungen durch Strom- oder Spannungsüberschläge bzw. Kurzschlüsse sind nachfolgend aufgeführte Sicherheitshinweise zum Betrieb des Gerätes unbedingt zu beachten.
  • Page 8 5995 ® PeakTech Bedienungsanleitung / operation manual Digitales AC/DC-Labornetzgerät / Digital AC/DC-power supply...

Table of Contents