Before powering up the motor, remove the control board dust cover and insert the AF43S receiver card.
To energize the display press Enter, to scroll use the < (left) or > (right) arrows. The display initiates at the
F1 command. Factory setting for Safety Functions is set as disabled.
Disengage the motor, position the gate halfway and re-engage the motor.
Select A1 & press Enter. From the Motor Size submenu select 1 for 400Kg, 2 for 600Kg, 3 for 800Kg or 4
for 1000Kg. Press Enter.
Factory Default setting is for a Left hand install, to change to Right hand, press Enter and scroll to F54, from
the submenu change from 0 to 1 and press Enter
Select A3 & press Enter. This will begin the Setup Calibration. Select 1 & press Enter. The gate will first
close and then reopen slowly; this will set up the limits and slow down positions automatically.
Adding Radio Transmitters
1. To enter the remote transmitters, < scroll to U1 and press Enter
2. Select a command for the user‟s remote. 1 = step – step (open – close) 2 = sequential (open – stop –
close- stop) 3 = open only, 4 = partial opening. Press Enter to confirm
3. The next available user slot (between 1 & 25) will start to flash. Press and release the remote button
to be programmed.
4. Press Esc to exit programming. You can clone this code from remote to remote. To add further users,
repeat the above steps, the next available user slot will be selected automatically, or you can choose
the slot number manually.
Adding P.E. Beams
To activate P.E. Beams, scroll to F2 (CX) & press Enter. Select the photocell operation, C1 = reopening
during closing, C2 = close when opening, C3 = partial stop, C4 = obstacle wait
Loop setup
For an opening loop, power from 10 & 11 (24V) and connect to 2 & 3P (open only, requires Auto Close)
For a safety loop, connect to 2 and either F2 (CX) or F3 (CY) whichever is available. Select functions as per
P.E. Beams
Auto Close
Scroll to F19 & press Enter. Select a value between 1 and 180 seconds
RIO
Insert the RIOCONN card with the power off. Power up and the RIOCONN‟s LED‟s flash BLUE.
Insert the battery into the accessory (do not put both batteries in at the same time, each unit is powered and
programmed individually), the LED‟s will flash RED. Press the PROG button on the RIOCONN for 2
seconds the LED‟s stay on. The accessory LED‟s will flash BLUE, press and hold the T1 button for 2
seconds. Programming is complete when the LED‟s turn off. Repeat this process for any additional
accessory. An E17 error may occur, turn the power to the motor off and then on again, there should be
nothing on the LED screen. If the RIOCEL is not aligned the CEL will beep and a "P1" error shows.
CAME Australia Pty Limited ABN 31 116 251 024
Unit 55, 11-21 Underwood Road, Homebush NSW 2140
T: (02) 9746 9991
F: (02) 9746 8891
SDN Slide Gate Programming
W: www.came.com.au

Advertisement

Table of Contents
loading

Summary of Contents for CAME SDN Series

  • Page 1 An E17 error may occur, turn the power to the motor off and then on again, there should be nothing on the LED screen. If the RIOCEL is not aligned the CEL will beep and a “P1” error shows. CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140...
  • Page 2 10. Ensure the front door is shut and locked at all times To change from LH to RH install Swap FA and FC plus M + N wires CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140 T: (02) 9746 9991 F: (02) 9746 8891 W: www.came.com.au...
  • Page 3: Fault Finding

    2 +7 check for voltage of 4.5vDC Sensitivity increase to reduce power, decrease to increase power CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140 T: (02) 9746 9991 F: (02) 9746 8891...
  • Page 4 9. Press setup, each gate leaf will cycle and set themselves *For Amico set dipsw 7 ON, for Frog J set dipsw 7 OFF CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140...
  • Page 5: Related Functions

    You can change the home screen by going to INFO <ENTER> scroll to STANDBY MSG. <ENTER> insert new msg. <ENTER> hold for at least ONE SECOND CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140...
  • Page 6: Basic Programming

    NOTE: to exclude the ENCODER FUNCTIONS if there are any PROBLEMS go to F11 and change the value to „1‟. CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140 T: (02) 9746 9991 F: (02) 9746 8891 W: www.came.com.au...
  • Page 7 To adjust the auto closing time scroll to TIMING ADJ <ENTER> and change the value from 0” to 120” CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140 T: (02) 9746 9991 F: (02) 9746 8891 W: www.came.com.au...
  • Page 8 The LED will flash 3 times to indicate memorisation CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140...
  • Page 9: Auto Close

    ACCESS CONTROL 2 + 3 for Opening, turn on Dipswitch 1 and set closing time on the A.C.T. trimmer. CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140 T: (02) 9746 9991 F: (02) 9746 8891 W: www.came.com.au...
  • Page 10 Automatic Gates – Access Control – Parking Equipment - Bollards AMICO INWARD OPENING AMICO OUTWARD OPENING CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140 T: (02) 9746 9991 F: (02) 9746 8891...
  • Page 11 Automatic Gates – Access Control – Parking Equipment - Bollards AXO INWARD OPENING AXO OUTWARD OPENING CAME Australia Pty Limited ABN 31 116 251 024 Unit 55, 11-21 Underwood Road, Homebush NSW 2140 T: (02) 9746 9991 F: (02) 9746 8891...

Table of Contents