Warning Device NVD-111
Commissioning
Switch setting ON – operating mode
The reaction time for detection of a fat layer is 24 hours (warning device in
n
normal mode, green "SYSTEM OK" LED lights up). The device becomes
active only after the fat level sensor has remained in a fat layer undisturbed
for a period of 24 hours.
The reaction time for detection of water is 1 hour (warning device in alarm
n
mode, red "FAT LAYER ALARM" LED lights up). The device becomes
active only after the fat level sensor has remained in water undisturbed for
a period of 1 hour.
Note!
Note that the "SYSTEM OK" LED light ups under the following conditions:
After switching on the warning device
n
After switching the DIP switch from OFF to ON
n
After pressing and holding the "ALARM RESET" button
n
(approximately 3 to 4 seconds)
The device becomes active only after the fat level sensor has remained in a fat
layer undisturbed for a period of 24 hours.
The device uses the "FAT LAYER ALARM" LED to display the alarm
n
status.
The device triggers an audible alarm where necessary.
n
The device activates the relay.
n
• The device uses the "FAT LAYER ALARM" LED to display the
alarm status.
• The device triggers an audible alarm where necessary.
• The device activates the relay.
• The "FAT LAYER ALARM" LED goes out.
• The "SYSTEM OK" LED flashes.