Summary of Contents for Keysight N5224AU-217

  • Page 1 Keysight Add Source and Receiver Attenuators Upgrade To Upgrade PNA N5224A or N5225A Option 201 to Option 217 Upgrade Kit Order Numbers: N5224AU-217 or N5225AU-217 Keysight Kit Number: N5225-60103 Installation Note...
  • Page 3: Warranty Statement

    SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL.
  • Page 4: Getting Assistance From Keysight

    Getting Assistance from Keysight By internet, phone, or fax, get assistance with all your test and measurement needs. Contacting Keysight Assistance with test and measurements needs and information on finding a local Keysight office are available on the Web at: http://www.keysight.com/find/assist If you do not have access to the Internet, please contact your Keysight field engineer.
  • Page 5: Getting Prepared

    The enclosed Option Entitlement Certificate is a receipt, verifying that you have purchased a NOTE licensed option for the PNA of your choice. You must now use a Keysight Web page to request a license key for the instrument that will receive the option.
  • Page 6 Downloading the Online PNA Service Guide To view the online Service Guide for your PNA model number, use the following steps: 1. Go to www.keysight.com. 2. In the Search box, enter the model number of the analyzer (Ex: N5242A) and click Search.
  • Page 7: Tools Required For The Installation

    Products affected ....... . . N5224A and N5225A Option 201 Installation to be performed by ..... . Keysight service center or personnel qualified by Keysight Estimated installation time .
  • Page 8 Items Included in the Upgrade Kit Check the contents of your kit against the following list. If any part is missing or damaged, contact Keysight Technologies. Refer to “Getting Assistance from Keysight” on page Table 1 Contents of Upgrade Kit N5225-60103...
  • Page 9 Table 1 Contents of Upgrade Kit N5225-60103 Description Part Number Desig. Ribbon cable, A23 test set motherboard J549 to A38 test port 1 source attenuator N5245-60006 Ribbon cable, A23 test set motherboard J546 to A41 test port 2 source attenuator Extra quantities of items such as protective plastic caps, screws, cable ties, and cable clamps NOTE may be included in this upgrade kit.
  • Page 10: Overview Of The Installation Procedure

    Installation Procedure for the Upgrade The network analyzer must be in proper working condition prior to installing this option. Any necessary repairs must be made before proceeding with this installation. This installation requires the removal of the analyzer’s protective outer covers. The analyzer WARNING must be powered down and disconnected from the mains supply before performing this procedure.
  • Page 11 If the model number, serial number, or option number do not match those on your license key, you will not be able to install the option. If this is the case, contact Keysight for assistance before beginning the installation of this upgrade.
  • Page 12 Step 3. Remove Some Bottom-Side (Test Set) Cables Be careful not to damage the center pins of the semirigid cables. Some flexing of the cables CAUTION may be necessary but do not over-bend them. 1. Place the analyzer bottom-side up on a flat surface. 2.
  • Page 13 Step 4. Assemble the A46 and A49 Receiver Attenuator Assemblies Refer to Figure 1 for this step of the procedure. New parts are listed in Table 1 on page 7. Use a T-10 TORX driver to tighten all screws. Figure 1 Port 1 and Port 2 Receiver Attenuator and Bracket Assembly Installation Note N5225-90103...
  • Page 14 Step 5. Install the A46 and A49 Receiver Attenuator Assemblies Refer to Figure 2 for this step of the procedure. New parts are listed in Table 1 on page 7. Use a T-10 TORX driver to tighten all screws. Figure 2 Port 1 and Port 2 Receiver Attenuator Assemblies Installation Installation Note N5225-90103...
  • Page 15 Step 6. Assemble the A38 and A41 Source Attenuator Assemblies Refer to Figure 3 for this step of the procedure. New parts are listed in Table 1 on page 7. Use a T-10 TORX driver to tighten all screws. Figure 3 Source Attenuator and Brackets Assembly Installation Note N5225-90103...
  • Page 16 Step 7. Install the A38 and A41 Source Attenuator Assemblies Refer to Figure 4 for this step of the procedure. New parts are listed in Table 1 on page 7. Use a T-10 TORX driver to tighten all screws. Figure 4 Source Attenuator Assemblies Installation Installation Note N5225-90103...
  • Page 17 Step 8. Install Some Bottom-Side (Test Set) Cables Follow instructions carefully when making cable connections, especially wire harness CAUTION connections. Incorrect connections can destroy components, resulting in additional customer costs. Install the Semirigid Cables To see an image showing the location of these cables, click the Chapter 6 bookmarks “Bottom RF Cables, 2- port Configuration, Option 217”...
  • Page 18 Figure 5 Location of Cable Clamps to Secure W33 • W104 (N5245-20057) A49 port 2 receiver attenuator to A27 mixer brick (B) • W47 (N5245-20119) REF 2 RCVR R2 IN to A27 mixer brick (R2) • W47 (N5245-20119) REF 2 RCVR R2 IN to A27 mixer brick (R2) •...
  • Page 19 If the two screws that attach the reference mixer switch to the test set deck were loosened, torque these screws now to 9 in-lbs. * As shown in Figure 6, install a cable tie (part number 1400-0249) to secure W21 (part number N5245- 20118).
  • Page 20 Step 9. Remove the Old Lower Front Panel Overlay Refer to Figure 7 for this step of the procedure. Although this figure shows a 4-port PNA, the concept is the same for a 2-port PNA. New parts are listed in Table 1 on page 1.
  • Page 21 Step 10. Reinstall Front Panel Assembly For instructions on reinstalling the front panel assembly, click the Chapter 7 bookmark “Removing and Replacing the Front Panel Assembly” in the PDF Service Guide Step 11. Install the New Lower Front Panel Overlay Refer to Figure 7 on page 19 for this step of the procedure.
  • Page 22 4. Using the keyboard, enter the license key in the box provided. The license key is printed on the the license message you received from Keysight. Enter this key exactly as it is printed on the message. 5. Click Enable.
  • Page 23 Perform the Operator’s Check to check the basic functionality of the analyzer. For instructions, click the Chapter 3 bookmark “Tests and Adjustments” in the PDF Service Guide If you experience difficulty with the basic functioning of the analyzer, contact Keysight. Refer to “Contacting Keysight”...
  • Page 24 This information is subject to change without notice. © Keysight Technologies 2011, 2013, 2014 August 2014 *N5225-90103* N5225-90103 www.keysight.com...