Memory And Performance - Cisco UCS B200 M3 Installation And Service Note

Blade server
Hide thumbs Also See for UCS B200 M3:
Table of Contents

Advertisement

CPU spares come with two syringes of thermal grease; one with a blue cap and one with a red cap. The
Note
syringe with the blue cap is used with this server.
Figure 15: Thermal Grease Application Pattern
Step 10
Replace the heat sink. See callout 4.
On certain models, heat sinks are keyed to fit into the plastic baffle extending from the motherboard. Do not
Caution
force a heat sink if it is not fitting well, rotate it and re-orient the heat sink.
Step 11
Secure the heat sink to the motherboard by tightening the four captive screws a quarter turn at a time in an X pattern
as shown in the upper right.

Memory and Performance

Installing Memory
To install a DIMM into the blade server, follow these steps:
Procedure
Step 1
Press the DIMM into its slot evenly on both ends until it clicks into place.
DIMMs are keyed. If a gentle force is not sufficient, make sure the notch on the DIMM is correctly aligned.
Be sure that the notch in the DIMM aligns with the slot. If the notch is misaligned you may damage the DIMM,
Note
the slot, or both.
Step 2
Press the DIMM connector latches inward slightly to seat them fully.