Memory Performance; Installing A Virtual Interface Card Adapter - Cisco UCS B460 M4 Installation And Service Note

Blade server with e7 v4 cpus
Hide thumbs Also See for UCS B460 M4:
Table of Contents

Advertisement

Memory Performance

The following figure shows the logical representation of the channels.
Figure 21: Logical Representation of Channels
Memory Performance
When configuring your server, consider the following:
• DIMMs within the blade can be of different speeds, but all DIMMs will run at the speed of the DIMM
• No mixing of DIMM type (LRDIMM, RDIMM, TSV-RDIMM) is allowed.
• Your selected CPU(s) can have some affect on performance. CPUs used must be of the same type.
• Mixing DIMM ranks and densities can lower performance.
• Unevenly populating DIMMs between CPUs can lower performance.

Installing a Virtual Interface Card Adapter

The Cisco UCS B260 M4 Blade Server and UCS 460 M4 Blade Server support the Cisco VIC 1300 Series
(VIC 1340 and VIC 1380). The Cisco VIC 1300 Series is compatible with UCS 6200 Series Fabric Interconnects
and the UCS 6300 Series Fabric Interconnects.
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v4 CPUs
28
with the lowest speed.
Servicing the Blade Server

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ucs b260 m4

Table of Contents