5.
Auxiliary function (only for documentation units)
5.1
Documentation
Your FRIAMAT
®
(switched off). The "Documentation" function is used to save the technical
fusion parameters. These can in each case be assigned to a commission
number and/or to an operator pass.
5.1.1 Switching on
This function is activated or deactivated by reading in a DOCUMENTATION
bar code (see plastic card in the accessories pouch). When the function is
activated the display will show the sequential number on the left and the
number of fusions which can still be stored on the right (and if applicable,
above these the appropriate commission number.)
5.1.2 Switching off
The DOCUMENTATION function can be deactivated by reading in the
DOCUMENTATION bar code again. The safety question of whether this is
required can be acknowledged by pressing the START button or rejected by
pressing the STOP button (breaking off with the STOP button will bring about
a return to the previous state).
18
model is supplied with the documentation deactivated
FRIAMAT
➔
2
Switch off
documentation ?
Code
499
Need help?