In The Event Of Power Failure - Laars SUMMIT SMB-200 User Information

Modulating condensing boiler
Table of Contents

Advertisement

Page 6
1E. Annual Inspection of Condensate
Drain System
Visually inspect the condensate drain lines. If
either clear plastic line appears to be full of
condensate (water), loosen the nut on the jacket that
retains the line and remove the line from the jacket
and clear any obstruction from the line. Replace line
and tighten nut.
1F. In the Event of Power Failure
The Summit cannot be operated during an
electrical power outage. If there is an extended power
outage with danger of freezing, then the Summit (and
all other water systems) should be completely drained.
When draining the Summit, turn off gas and turn off
main power switch. When replacing in service, refer
to start-up instruction for proper filling and purging.
1G. Full Service Every Three Years
In addition to the annual visual inspections by
the owner, a qualified service agency should conduct
a detailed inspection of all flue product carrying areas
of the boiler and vent system. This should be done in
accordance with the service instruction in the
"Installation and Operating Instructions Manual" for
the Summit.
Figure 2. Components Identification.
LAARS HEATING SYSTEMS
WARNING
Do not use this boiler if any part may have been
under water. Immediately call a qualified service
technician to inspect the boiler and to replace any
part of the control system and any gas control which
may have been under water.
WARNING
Should overheating occur or the gas supply fail to
shut off, do not turn off or disconnect the electrical
supply to the pump. Instead, shut off the gas supply
at a location external to the appliance.
AVERTISSEMENT
En cas de surchauffe ou si l'admission de gaz ne
peut être coupée, ne pas couper ni débrancher
l'alimentation électrique de la pompe. Fermer plutôt
le robinet d'admission de gaz à l'extérieur de
l'appareil.
FOR SERVICE
Contact your installing contractor, gas utility, Laars
dealer or call Laars for the nearest authorized
representative in your area.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Summit smb-250

Table of Contents