  • Page 1 2 0 0 Blizzard Lighting, LLC http://www.blizzardpro.com Waukesha, WI USA Copyright (c) 2019...
  • Page 2: Table Of Contents

    DMX Channel Values In-Depth Gobo Replacement Rotating Gobos Static Gobos 5. Appendix Keeping Your G-Max™ 200 As Good As New Returns (Gasp!) Shipping Issues Tech Specs Troubleshooting Dimensional Drawings Photometric Data Page 2 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 3: G-Max™ 200

    Blizzard Lighting™ assumes no responsibility or liability for any errors or omissions that may appear in this user manual. Blizzard Lighting™ reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time.
  • Page 4: Safety Instructions (Don't Stick Your Hand In The Toaster!)

    Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please open a support ticket at www. blizzardpro.com/support. Page 4 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 5: Meet The G-Max™ 200

    Color Wheel Gobo Wheel #1 (Static) Gobo Wheel #2 (Rotating) Gobo Rotation Iris Frost Prism Select Prism 1 Rotation Prism 2 Rotation Zoom (narrow <-> wide) Focus Reset Fixture Page 5 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 6: The G-Max™ 200 Pin-Up Picture

    Figure 1: The G-Max™ 200 Pin-Up Picture 200W White LED Head/Arms Light Source 5-Button Control Panel Menu with LCD Display Figure 2: The Rear Connections DMX Inputs Power Input DMX Outputs Power Output Fuse Page 6 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 7: Setup

    Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor & shield – 55 pF/ft. Maximum resistance of 20 ohms / 1000 ft. Nominal impedance 100 – 140 ohms Page 7 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 8: Cable Connectors

    Step 3: Connect other fixtures in the chain from output to input as above Place a DMX terminator on the output of the final fixture to ensure best communication. Page 8 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 9: Fixture Linking (Master/Slave Mode)

    • Safety cables MUST ALWAYS be used. • Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. Page 9 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 10: Mounting Points

    Please be aware, you should have a qualified electrician performing all of your electrical connection needs. Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet. Page 10 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 11: Clamp Mounting

    Be sure to only use the designated rigging point found on the underside of the base assembly for the safety cable. Page 11 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 12: Operating Adjustments

    Press the <OK> button to enable a menu option. To return to the previous option or menu without chang- ing the value, press the <LEFT> button. Page 12 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 13: Control Panel Menu Structure

    Calibration (01-10) Return <OK> Return to Main Menu View DMX Channel -- 000-255 View current DMX channel values Return <OK> Return to Main Menu Reset <OK> Reset fixture Page 13 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 14 Gobo 2 Shake - 4 Dots 108 <-> 114 Gobo 1 Shake - Plus 115 <-> 185 Wheel Spin Forward (fast <-> slow) 186 <-> 255 Wheel Spin Reverse (slow <-> fast) Page 14 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 15: Dmx Channel Values In-Depth

    000 <-> 255 Zoom (narrow <-> wide) 000 <-> 255 Focus Reset (can be enabled or disabled in menu) 000 <-> 127 No Function 128 <-> 255 Reset Page 15 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 16: Gobo Replacement

    3) Using a small tool, pry the tension ring from the gobo holder. 4) Remove the old gobo, insert the new gobo, and replace in the reverse steps of removal. Gobo holder Gobo Tension ring Rotating Gobos Static Gobos Page 16 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 17: Appendix

    Damage incurred in shipping is the responsibility of the shipper, and must be reported to the carrier immediately upon receipt of the items. Claims must be made within seven (7) days of receipt. Page 17 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 18: Tech Specs

    Fixture Not Respond- Make sure all connectors are seated properly and securely. ing / Responding Use Only DMX Cables. Erratically Install a Terminator. Check all cables for defects. Reset fixture(s). Page 18 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 19: Dimensional Drawings

    5m lux 5m fc 7.5m lux 7.5m fc 10m lux 10m fc 13° 38,405 3,567.9 9,937 923.2 4,668 433.7 2,746 255.1 27° 13,058 1,213.2 3,241 301.1 1,543 143.4 85.1 Page 19 G-Max™ 200 Manual Rev. A © 2019 Blizzard Lighting, LLC...
  • Page 20 Enjoy your product! Our sincerest thanks for your purchase! --The team @ Blizzard Lighting...