Beko BEKOMAT 12 Instructions For Installation And Operation Manual page 12

Advertisement

Electrical data • Caracteristicas eléctricas
Charactéristiques electrique • Dados eléctricos
Max. power input
absorbida y fusible recomendado
Consommation maximale
Potência máx. absorvida
Supply voltage (see type plate)
Tensión de entrada (ver etiqueta identificativa)
Alimentation électrique (voir plaque sign.)
Tensão de rede (ver placa indicadora)
Recommanded cable jacket diameter
Diámetro exterior del cable recomendado
diamètre recommandé pour la gaine du câble
Diâmetro recomendado do invólucro de cabo
Recommanded cable cross-section and fuse
protection
Sección de cable y fusible recomendado
Section recommandé des fils et fusibles
Secção recomendadodo cabo e fusível
recomendado
Contact loading
Carga del contacto
Pouvoir de coupure
Carga de contato
Maintenance • Mantenimiento • Entretien • Manutenção
12
230/115/24/...
VAC
P < 2,0 VA
Uac = ... ±10%
50 – 60 Hz
ø 5,8 - 8,5 mm
3 x 0,75 mm² / 5 x 0,25 mm²
0,5 A *)
< 250 VAC / < 0,5 A
> 12 VDC / > 50 mA
x
x
Potential-free contact
24 VDC
The alarm signal can be relayed via a
potential-free contact. The changeover
contact can be operated, e.g., in the fail-
P < 2,0 W
safe mode.
When operating voltage is being applied
and the BEKOMAT device is functioning
U
= 24 VDC
correctly, the alarm relay is energized.
0
The contact element (0.7 - 0.8).
-10/+25%
When there is no operating voltage or
in the case of a fault signal, the alarm
relay drops out. The contact element is
open (alarm).
Externeral test button (optional)
Here, the normal test button function
has been extended for additional use
outside the BEKOMAT unit. This makes
100 mA *) **)
it possible to discharge any condensate
in the unit by remote control, if required.
When the external contact closes, the
valve will open.
*) time lag
**) min. internal resistance of
voltage source Ri> 12 Ohm
Maintenance recommendation:
• Housing and valve should be cleaned
once a year.
• Replace wearing parts once a year.
x
Set of wearing parts ( x )
x
BEKOMAT 12
x
BEKOMAT 12 CO
x
BEKOMAT 12 CO PN63
x
x
x
Functional test of BEKOMAT device:
• Briefly press test button 2 sec.
• Valve opens for condensate dis-
charge.
Checking of alarm signal:
• Shut off condensate inflow.
• Press test button for at least 1 minute.
• Red LED flashes (after 1 minute).
• Alarm signal is being relayed.
BEKOMAT 12, 12 CO, 12 CO PN63
english
XE KA12 101
XE KA12 101