commencing any electrical work!
Risk of fire!
• The device is secured and held in the ceiling
cut-out by means of four retaining clamps.
The edge of the ceiling cut-out must have a
sufficient load-bearing capacity for securing
the radiant heater.
• The ceiling cut-out must have the
dimensions 305 to 310 mm x 510 to 580
mm.
• When installing the device, no supporting
elements such as joists, rafters or roof
battens should be damaged.
• Under no circumstances should the cavity
above the radiant heater be filled with
insulating material or other materials.
• Sufficient air exchange for heat dissipation
must be ensured in the cavity above the
radiant heater.
• The device is equipped with a mains lead
fitted with a grounding type plug without a
switch. The device must be switched on and
off by means of a locally installed switch.
Only commission the device after it has
been fully installed.
COMMISSIONING
• After switching on the device when
commissioning it for the first time as well
as after a lengthy period of non-use, it is
possible that odors may be emitted for a
short while.
CLEANING
• First disconnect the device from the mains.
• Once cooled down, it is possible to wipe
down the frame dry.
• Do not touch quartz bars with fingers, as
doing so can leave marks and cause them to
fail.
• The reflector should be cleaned at regular
intervals from outside with a paint brush.
• Do not use abrasive or caustic detergents!
• Never immerse the device in water! Risk of
fatal injury!

CUSTOMER SERVICE

• Only authorized professionals are permitted
to perform repairs to the device!
Important! Unprofessional tampering
invalidates all warranty entitlement.
4
Infraflex IHA15/20
• Improper repairs can result in considerable
risks for the user!

TECHNICAL DATA

Color: White or silver
Casing: Sheet steel, varnished
Cord length: 2.9 m with grounding type plug
Switching on/off: Via separate light switch to
be installed (locally) by the electrician
Application: Indoors
Technical Data
Connection/fuse: 230/240 Volt (50/60 Hz)
with 16 Amp B or C (= slow-blowing fuse)
Output: 1500 Watt / 2000 Watt
Infrared tube: HANA 'Gold Tube'
Guaranteed service life: 5000 hours (approx.
10-15 years with average use)
Type of protection: IP 20
Dimensions (W x D x H): 600 mm x 325 mm x
110 mm
Weight: 4.55 kg
Installation depth: min. 450 mm
Cut-out length/width: 305 to 310mm x 510 to
580 mm
Ceiling panel/panel thickness: max. 15 mm