LIMITED WARRANTY
SHURflo warrants FLOport Gas Pump model
and workmanship defects (under normal use and service) for a period of five (5)
year from the date of manufacture.
The limited warranty will not apply to pumps that were improperly installed,
misapplied, or not suitable with components of other manufacturers. The limited
warranty will not apply to pumps subjected to fluids that are incompatible with pump
materials, or pumps operated by a contaminated air supply.
warrant any pump that is physically damaged or modified outside the SHURflo
factory.
All FLOport gas pumps are to be returned to SHURflo Ltd., West Sussex, England, postage
prepaid.
Package returns carefully; SHURflo is not responsible for damage.
SHURflo's obligation under this warranty policy is limited to repair or replacement.
Pumps found not defective (under the terms of this limited warranty) are subject to
charges to be paid by the returnee for the testing and packaging of "tested good"
units.
No credit or labor allowances will be given to the returnee for pumps returned as
defective.
Warranty replacements will be shipped on a freight allowed basis.
SHURflo reserves the right to choose the method of transportation.
This limited warranty is in lieu of all other warranties, expressed or implied, and no
other person is authorized to give any other warranty or assume obligation or liability
on SHURflo's behalf. SHURflo shall not be liable for any labor, damage or other
expense, nor shall SHURflo be liable for any indirect, incidental or consequential
damages of any kind incurred by the reason of the use or sale of any defective
product or part. This limited warranty covers beverage products distributed within
the United States of America. Other world market areas should consult with the
distributor for any deviation from this document.
« « « «
ISO Certified Facility
SHURflo reserves the right to update specifications, prices, or make substitutions.
SHURflo « « « «
5900 Katella Avenue
Cypress, CA 90630
Elkhart, IN 46514-5427
(800) 854-3218 (562) 795-5200
FAX (562) 795-7564
Shipping: 5900 Katella Ave., Suite B
Cypress, CA 90630
911-532 Rev. A 03/02
#
166-226-XX to be free from material
SHURflo will not
R
a WICOR Company
SHURflo East
SHURflo Ltd.
52748 Park Six Court
Unit 5 Sterling Park
Gatwick Road, Crawley
((800) 762-8094
West Sussex, RH10 2QT
(219) 262-0478
United Kingdom
FAX (219) 264-2169
+44 1293 424000
© 1998 Printed in USA
FAX +44 1293 421880
H.D.A. FLOport
Installation and Operation Manual
LIQUID OUTLET FITTING
REMOVAL / INSTALLATION:
1. Remove the CO
Operate the dispenser valve to relieve all
pressure within the outlet tubing.
2. Rotate the Locking Collar clockwise a ¼
turn and allow the Locking Collar and
outlet fitting to drop down.
3. Slide the fitting sideways through opening
in the Locking Collar.
4. Install in reverse order.
*Q.D. operation for CO
inlet fittings illustrated on page: 3.
PUMPING CAPABILITY
Due to diversity of both the installations and equipment used within beverage
systems, it is difficult to calculate/predict total pumping distance. The ability to
deliver fluid is limited by the dynamics of the fluid (flow) and pump displacement at
pressure. Consider the following factors when estimating pressure drop within a
beverage system.
Fluid viscosity and temperature.
Inside diameter of the inlet/outlet tubing, fittings, etc.
Total flow rate of valve(s) connected to a pump.
Horizontal distance of the outlet tubing.
The pressure drop per foot within vertical tubing runs is significant. To estimate the
losses use the appropriate distance given by Max. Horz. Dist. Chart. Take 3% of that
distance. Multiply the vertical distance by that number. Subtract the product from the
original Max. Horz. distance. The result is the total tubing run (includes vertical) that
should be attempted for that flow rate, tubing I.D., and viscosity.
MAXIMUM HORIZONTAL DISTANCE by VISCOSITY
TABLES ARE TO BE USED AS A GUIDELINE ONLY
SYRUP TYPE/VISCOSITY
Standard Sugar (15-30 cP.)
Heavy Soda (30-45 cP.)
Diet soda syrups are substantially less viscous (3 cP.) The tables above are the
results of tests conducted with 5.8 bar (to the pump), with a minimum of 2.38 bar at
the dispenser valve (to maintain brix). Ambient temperature = 21°C.
Page: 4 of 4
911-532 Rev. A 03/02
BEVERAGE GAS PUMP (166-226-XX)
/gas inlet fitting*.
2
/gas and liquid
2
(Centipose = cP.)
FLOWRATE
10
15 cc/sec
30 cc/sec
15 cc/sec
30 cc/sec
I.D. TUBING
MM
152+ meters
118 meters
150 meters
73 meters