INDUSTRIAL PUMP 8000 SERIES
Installation and Operation Manual
SHURflo offers various pump models for different applications. The
information outlined by this manual is general, and not specific to all 8000
series pumps. Be certain the pumps' materials will be compatible with the
fluid being pumped. 8000 series pumps are intended for intermittent or
continuous duty when the proper operating criteria is met. Product Data
Sheets outlining specific thermal limits, load, flow curves, and other technical
information for a particular model are available. If unsure of the chemical
compatibility with a given elastomer or the motors intended design, please
call SHURflo for assistance.
CAUTION:
frequently started within a period of time that would cause the motor to
reach its maximum thermal limits. Once the maximum thermal limit is
obtained, the motor must be allowed to return to ambient temperature
before resuming operation.
CAUTION:
the pump in an explosive environment. Arcing from the motor brushes,
switch or excessive heat from an improperly cycled motor may cause an
explosion.
CAUTION: DO NOT assume fluid compatibility. If the fluid is improperly
matched to the pumps' elastomers, a leak may occur. Pumps used to
transfer hazardous or hot (max. temperature 170°F [76°C] Viton
chemicals must be in a vented area to guard against the possibility of injury
due to harmful or explosive liquid/vapors.
CAUTION: DO NOT operate the pump at pressures which cause the motor
to exceed the amperes rating indicated on the name plate. Various pump
models are equipped with thermal breakers to interrupt operation due to
excessive heat. Once the temperature of the motor is within proper limits it
911-314 Rev. P 10/02
"Intermittent Duty" is defined as; operated and/or
DO NOT use to pump flammable liquids. Never operate
only)
Page: 1 of 8

Advertisement

loading
Need help?

Need help?

Do you have a question about the 800X-X4 series and is the answer not in the manual?

Questions and answers

Summary of Contents for SHURflo 800X-X4 series

  • Page 1 INDUSTRIAL PUMP 8000 SERIES Installation and Operation Manual SHURflo offers various pump models for different applications. The information outlined by this manual is general, and not specific to all 8000 series pumps. Be certain the pumps' materials will be compatible with the fluid being pumped.
  • Page 2: Bypass Operation

    (*ON/OFF within 2 sec.). If the pump is subjected to rapid cycling during normal operation, or for infrequent periods, damage may occur. Applications which exhibit rapid cycling should have restrictions in the outlet minimized. If not feasible consider a SHURflo Accumulator or a SHURflo "bypass" model pump. BYPASS OPERATION...
  • Page 3 switch may operate for several seconds even though the discharge side has been closed off. Models equipped with a bypass only will continue to run until power is turned OFF.
  • Page 4 If mounted within an enclosure, provisions to cool the motor may be necessary. Heat sinks which attach to the motor are available from SHURflo if increased heat dissipation is necessary. CAUTION: DO NOT locate the motor near low temperature plastics or combustible material.
  • Page 5 • If a check valve is installed in the plumbing it must have a cracking pressure of no more than 2 psi [.14 bar]. NOTE: SHURflo does not recommend the use of metal fittings or rigid pipe to plumb the inlet/outlet ports. Standard plastic male and female threaded fittings can be acquired at commercial plumbing supply stores.
  • Page 6 • The pump should be on a dedicated (individual) circuit, controlled with a double pole switch rated at or above the fuse ampere (UL/C-UL certified) indicated by the pump motor label. Depending on distance of the power source from the pump and ampere load on the circuit, wire may need to be heavier than indicated by the chart.
  • Page 7 The information outlined by this manual is general, and not specific to all 8000 series pumps. Contact the factory for a Product Data Sheet outlining technical information for a particular model.
  • Page 8: Troubleshooting

    TROUBLESHOOTING PUMP WILL NOT START: PUMP WILL NOT SHUT-OFF: switch equip.) Pressure  Fuse or breaker  For correct voltage and electrical  Output line closed and no leaks (±10%) connections  For air trapped in outlet line or pump head ...
  • Page 9: Service Kits

    Repair kits include simple illustrated instructions allowing easy installation. To insure that the correct kit is received the model numbered and all name plate data must be included with the order. Contact a SHURflo distributor or SHURflo directly to order the necessary repair kit. KEY#...
  • Page 11: Return Policy

    SHURflo's behalf. SHURflo shall not be liable for any labor, damage or other expense, nor shall SHURflo be liable for any indirect, incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product or part.
  • Page 12 SHURflo  SHURflo Ltd.  SHURflo East 5900 Katella Ave. 52748 Park Six Court Unit 5 Sterling Park Cypress, CA 90630 Elkhart, IN 46514-5427 Gatwick Road, Crawley (800) 854-3218 (562) 795-5200 (800) 762-8094 West Sussex, RH10 2QT FAX (562) 795-7564...