Download Print this page

SHURflo Blaster Series Installation And Operation Manual

Wash-down pump

Advertisement

Quick Links

INSTALLATION AND OPERATION MANUAL
DOWN PUMP
SHURflo's Blaster series pumps are designed to handle the harsh
marine environment.
Blaster motors have precision ball bearings
supporting the armature. Each motor is protected by an integral thermal
breaker, and are all U/L Marine listed. Blaster pressure switches are
sealed and the motors are finished with a baked-on polyurethane
coating to inhibit corrosion. The "Pro-Blaster" motor is sealed in an
exceptionally tough epoxy powder coated finish, allowing it to be in
environments where "splashed water" may be present. Blaster series
pumps are enclosed to prevent incidental moisture from entering;
however, they are not submersible units.
DUTY CYCLE
Wash-down pumps are rated for intermittent duty (only), as they operate at higher than average pressures. Operating a pump continuously for more
than twenty (20) minutes, within an hour period, is not recommended. Actual duty cycle is determined by amp draw, temperature, and rate of cycling.
NOTE: Rapid cycling should be minimized to ensure long life. Rapid cycling is defined as
911-444 Rev. E
10/98
MOUNTING
• Consider a dry location that allows easy access
if maintenance is required. The pump should
not be located in an area of less than one cubic
foot unless adequate ventilation is provided.
Excessive heat may trigger the integral thermal
breaker and interrupt operation. When the
temperature drops the breaker will automatically
reset and start operation.
• Mount higher than the outside water (sea)
level. The pump is capable of a 6 ft. [2
vertical prime above the outside water level.
The pump can be mounted in any position. If
mounting the pump vertically, the pump head
should be in the down position.
BLASTER 
SERIES WASH-
CAUTION: Do not drive screws through the
vessel's hull.
]
M
The Blaster delivers water on demand. With the spray nozzle off
the pump will turn off. As the nozzle is opened the pressure
side closed)
within the hose
(output side)
predetermined point the pumps pressure switch closes and the pump
operates. With the nozzle set at a fine mist the pump will cycle, as it is
able to pressurize the hose faster than water being released. If the spray
nozzle is held wide open the pump will operate continually. The pump
may momentarily operate even after the nozzle is closed, as it
pressurizes the hose. Once the pressure setting is reached the switch
opens and the pump stops.
/
within two seconds.
ON
OFF
• Use
pump. Choose a solid surface
stringer)
mounting feet are intended to isolate the pump
from the mounting surface; over-tightening,
flattening, or oversized screws will reduce the
mounting pads ability to isolate vibration/noise.
ELECTRICAL
• The pump should be on a dedicated
(individual)
red) lead with the proper size "slow blow"
fuse.
fuse, on 24
The total current draw on the circuit must not
exceed 15 amps.
drops. Once the pressure drops below a
#
8 stainless steel hardware to fasten the
that will not amplify pump sound. The
circuit protected on the positive (+
For all 12
pumps use a 15 amp
VDC
pumps use a 10 amp fuse.
VDC
(output
(bulkhead or

Advertisement

loading

Summary of Contents for SHURflo Blaster Series

  • Page 1 BLASTER  SERIES WASH- INSTALLATION AND OPERATION MANUAL DOWN PUMP SHURflo's Blaster series pumps are designed to handle the harsh marine environment. Blaster motors have precision ball bearings The Blaster delivers water on demand. With the spray nozzle off (output supporting the armature.
  • Page 2 PLUMBING • An ignition protected switch (U/L approved • Inlet tubing • SHURflo swivel barb fittings provide easy from the sea-cock (½"I.D. min.) marine duty) rated at or above 15 amps is valve to the pump should be rated for removal if maintenance or access is required.
  • Page 3 STRAINER / FILTRATION sufficient capacity under most on conditions. CAUTION: The strainer must be mounted above The interval for cleaning will be determined by the outside water line to prevent water from A wash-down system is only as dependable as the amount of debris encountered.
  • Page 4: Troubleshooting

    (Europe) !" For mounting feet that are loose or compressed too tight. !" For loose pump head or drive screws. SHURflo pump models with the mark printed on the motor label !" The motor with pump head removed . Is noise from motor or...
  • Page 5: General Safety Precautions

    "Plumbing is Disconnected". LIMITED WARRANTY SHURflo warrants Blaster series pumps to be free from material and workmanship SHURflo's obligation under this warranty policy is limited to the repair or defects under normal use and service for a period of one year from the date of replacement of the pump.